EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

1 H and 31 P MRS Interleaved With High Time Resolution Reveals Closely Matching Creatine CH₂ and PCr Dynamics During Exercise

Radka Klepochová iD, Fabian Niess iD, Matthäus Metz, Barbara Ukropcová, Jozef Ukropec, Siegfried Trattnig, Alexandra Kautzky-Willer iD, Martin Krššák, Martin Meyerspeer iD

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.70132 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Radka Klepochová und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine III, Division of Endocrinology and Metabolism, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Phosphocreatine, Creatine, Exercise, Proton Magnetic Resonance Spectroscopy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Science Fund (FWF), COMPose.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rate of intramuscular phosphocreatine (PCr) depletion and recovery in response to exercise estimated from 31 P MRS is an established measure for oxidative capacity. The creatine CH 2 resonance in 1 H MRS is known to exhibit a similar pattern. So far, repeating the exercise for consecutive 1 H and 31 P experiments posed limitations on the interpretation. Acquiring both datasets in a single time‐resolved experiment allows for direct quantitative comparison of creatine‐CH 2 and PCr kinetics. This can help answer to what extent creatine‐CH 2 mimics PCr dynamics and provide data on the visibility of myocellular creatine. Twenty‐seven volunteers, assigned to a group with lower BMI ( n = 16, BMI = 22.1 ± 3.2 kg/m 2 , age = 35.7 ± 9.3 years) or higher BMI ( n = 11, BMI = 34.1 ± 3.6 kg/m 2 , age = 35.0 ± 6.6 years) were measured on a 7 T MR system and MR‐compatible ergometer. Localized 1 H and 31 P MR spectra were acquired interleaved during a single 5‐min submaximal exercise effort and recovery, with 6 s time resolution. Exercise led to reduced creatine‐CH 2 signal, while the CH 3 resonance remained stable. Neither the recovery nor exercise‐on‐kinetics time constants were significantly different when quantified from 1 H or 31 P MR spectra in each group (recovery, lower BMI: τ PCr‐recovery = 35 ± 12 s vs. τ Cr–CH2‐recovery = 36 ± 11 s, higher BMI: τ PCrrecovery = 65 ± 30s vs. τ Cr–CH2‐recovery = 60 ± 11 s, and exercise‐on, lower BMI: τ PCr‐on‐kinetics = 39 ± 14 s vs. τ Cr–CH2‐on‐kinetics = 38 ± 15 s, higher BMI: τ PCr‐on‐kinetics = 77 ± 53 s vs. τ Cr–CH2‐on‐kinetics = 70 ± 53 s). Significantly different time constants between the groups distinguished by BMI were detected, likewise with 1 H and 31 P MRS. Interestingly, though, creatine‐CH 2 and PCr depletion differed, correlating positively. Closely matching Cr–CH₂ and PCr kinetics was confirmed for the first time in single time‐resolved experiments, using interleaved 1 H and 31 P MRS. The strong correlation between τ PCr and τ Cr–CH₂ and preserved intergroup differences suggests that quantifying Cr–CH₂ by 1 H MRS might, within limitations, serve as a surrogate for the estimation of oxidative capacity via PCr from 31 P MR spectra. The results contribute to the discussion on NMR visibility of myocellular creatine pools.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhosphocreatineCreatineExerciseProton Magnetic Resonance SpectroscopyHumansAdultMaleFemaleMagnetic Resonance SpectroscopyPhosphorus IsotopesTime FactorsKinetics

Stichwörter der Autor:innen

PCr and Cr–CH2 exercise‐on kinetics ratePCr and Cr–CH2 recovery ratecreatine visibilityhuman volunteersproton and phosphorus magnetic resonance spectroscopyskeletal muscle metabolism

Substanzen

PhosphocreatineCreatinePhosphorus Isotopes

Autor:innen und Institutionen

  • Department of Internal Medicine III, Division of Endocrinology and Metabolism, Medical University of Vienna, Vienna, Austria.
  • High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia.
  • Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia.
  • Faculty of Medicine, Institute of Pathophysiology, Comenius University, Bratislava, Slovakia.
  • High-Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.

ORCID-Profile: Radka Klepochová, Fabian Niess, Alexandra Kautzky-Willer, Martin Meyerspeer

Förderung

  • Austrian Science Fund (FWF)
  • COMPose

Zitieren

APA

Klepochová, R., Niess, F., Metz, M., Ukropcová, B., Ukropec, J., Trattnig, S., Kautzky-Willer, A., Krššák, M., & Meyerspeer, M. (2025). 1 H and 31 P MRS Interleaved With High Time Resolution Reveals Closely Matching Creatine CH₂ and PCr Dynamics During Exercise. NMR in Biomedicine. https://doi.org/10.1002/nbm.70132

Vancouver

Klepochová R, Niess F, Metz M, Ukropcová B, Ukropec J, Trattnig S, et al. 1 H and 31 P MRS Interleaved With High Time Resolution Reveals Closely Matching Creatine CH₂ and PCr Dynamics During Exercise. NMR in Biomedicine. 2025. doi:10.1002/nbm.70132

BibTeX
@article{Klepochov2025,
  author = {Klepochová, Radka and Niess, Fabian and Metz, Matthäus and Ukropcová, Barbara and Ukropec, Jozef and Trattnig, Siegfried and Kautzky-Willer, Alexandra and Krššák, Martin and Meyerspeer, Martin},
  title = {1 H and 31 P MRS Interleaved With High Time Resolution Reveals Closely Matching Creatine CH₂ and PCr Dynamics During Exercise},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.70132}
}
Kostenlos starten →