Multiparametric MRI Can Detect Enhanced Myelination in the Ex Vivo Gli1 −/− Mouse Brain
NMR in Biomedicine · 2025
DOI: 10.1002/nbm.70025 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Choong H Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New Yor…. Hauptthemen laut MEDLINE: Myelin Sheath, Brain, Zinc Finger Protein GLI1, Multiparametric Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 92 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIBIB NIH HHS, NINDS NIH HHS.
Abstract (Originalsprache)
This study investigated the potential of combining multiple MR parameters to enhance the characterization of myelin in the mouse brain. We collected ex vivo multiparametric MR data at 7 T from control and Gli1 −/− mice; the latter exhibit enhanced myelination at Postnatal Day 10 (P10) in the corpus callosum and cortex. The MR data included relaxivity, magnetization transfer, and diffusion measurements, each targeting distinct myelin properties. This analysis was followed by and compared to myelin basic protein (MBP) staining of the same samples. Although a majority of the MR parameters included in this study showed significant differences in the corpus callosum between the control and Gli1 −/− mice, only T 2 , T 1 /T 2 , and radial diffusivity (RD) demonstrated a significant correlation with MBP values. Based on data from the corpus callosum, partial least square regression suggested that combining T 2 , T 1 /T 2 , and inhomogeneous magnetization transfer ratio could explain approximately 80% of the variance in the MBP values. Myelin predictions based on these three parameters yielded stronger correlations with the MBP values in the P10 mouse brain corpus callosum than any single MR parameter. In the motor cortex, combining T 2 , T 1 /T 2 , and radial kurtosis could explain over 90% of the variance in the MBP values at P10. This study demonstrates the utility of multiparametric MRI in improving the detection of myelin changes in the mouse brain.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
- Department of Neuroscience and Physiology, Neuroscience Institute, New York University Grossman School of Medicine, New York, New York, USA.
Förderung
- NIH HHS
- NIBIB NIH HHS
- NINDS NIH HHS
- National Institute of Child Health and Human Development
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke
Zitieren
APA
Lee, C. H., Holloman, M., Salzer, J. L., & Zhang, J. (2025). Multiparametric MRI Can Detect Enhanced Myelination in the Ex Vivo Gli1 −/− Mouse Brain. NMR in Biomedicine. https://doi.org/10.1002/nbm.70025
Vancouver
Lee CH, Holloman M, Salzer JL, Zhang J. Multiparametric MRI Can Detect Enhanced Myelination in the Ex Vivo Gli1 −/− Mouse Brain. NMR in Biomedicine. 2025. doi:10.1002/nbm.70025
BibTeX
@article{Lee2025,
author = {Lee, Choong H and Holloman, Mara and Salzer, James L and Zhang, Jiangyang},
title = {Multiparametric MRI Can Detect Enhanced Myelination in the Ex Vivo Gli1 −/− Mouse Brain},
journal = {NMR in Biomedicine},
year = {2025},
doi = {10.1002/nbm.70025}
}
EUVIMED