EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Road to a Realistic 3D Model for Estimating R 2 and R 2 * Relaxation Versus Gd‐DTPA Concentration in Whole Blood and Brain Tumor Vasculature

Daniëlle van Dorth iD, Ahmad Alafandi, Sadaf Soloukey iD, Pieter Kruizinga iD, Krishnapriya Venugopal iD, Aurélien Delphin iD, Dirk H J Poot iD, Thomas Christen iD, Marion Smits iD, Jeroen de Bresser iD, Juan A Hernandez-Tamames iD, Matthias J P van Osch iD

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.5308 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Daniëlle van Dorth und 11 weiteren Autor:innen. Beteiligte Einrichtung: C. J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands. Hauptthemen laut MEDLINE: Brain Neoplasms, Imaging, Three-Dimensional, Gadolinium DTPA, Magnetic Resonance Imaging. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dutch Research Council (NWO), Medical Delta, Nederlandse Organisatie voor Wetenschappelijk Onderzoek.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dynamic susceptibility contrast (DSC) MRI is commonly part of brain tumor imaging. For quantitative analysis, measurement of the arterial input function and tissue concentration time curve is required. Usually, a linear relationship between the MR signal changes and contrast agent concentration ([Gd]) is assumed, even though this is a known simplification. The aim of this study was to develop a realistic 3D simulation model as an efficient method to assess the relationship between Δ R 2 (*) and [Gd] both in whole blood and brain tissue. We modified an open‐source 3D simulation model to study different red blood cell configurations for assessing whole‐blood Δ R 2 (*) versus [Gd]. The results were validated against previously obtained 2D data and in vitro data. Furthermore, hematocrit levels (30%–50%) and field strengths (1.5–3.0–7.0 T) were varied. Subsequently, realistic tumor vascular networks were derived from intraoperative high framerate Doppler ultrasound data to study the influence of vascular structure and orientation with respect to the main magnetic field (1.5–3.0–7.0 T) for the calculation of Δ R 2 (*) versus [Gd] in brain tissue. For whole blood, good agreement of the 3D model was found with in vitro and 2D simulation data when red blood cells were aligned with the blood flow. For brain tissue, minor differences were found between the vascular networks. The effect of vessel direction with respect to B 0 was apparent in case of clear directionality of the main vessels. The dependency on field strength agreed with previous reports. In conclusion, we have shown that the relationship between Δ R 2 (*) and [Gd] is affected by the organization of red blood cells and orientation of blood vessels with respect to the main magnetic field, as well as the field strength. These findings are important for further optimization of the realistic 3D model that could eventually be used to improve the estimation of hemodynamic parameters from DSC‐MRI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain NeoplasmsImaging, Three-DimensionalGadolinium DTPAMagnetic Resonance ImagingHumansComputer SimulationContrast MediaHematocritModels, BiologicalErythrocytesReproducibility of Results

Stichwörter der Autor:innen

arterial input functiondynamic susceptibility contrast MRI (DSC‐MRI)hematocrit dependencymagnetic field strengthoxygen saturationsimulations

Substanzen

Gadolinium DTPAContrast Media

Autor:innen und Institutionen

  • C. J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
  • Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
  • Department of Neuroscience, Erasmus MC, Rotterdam, The Netherlands.
  • Department of Neurosurgery, Erasmus MC, Rotterdam, The Netherlands.
  • Inserm, CHU Grenoble Alpes, CNRS, IRMaGe, Université Grenoble Alpes, Grenoble, France.
  • Inserm, U1216, Grenoble Institut Neurosciences, GIN, Université Grenoble Alpes, Grenoble, France.

ORCID-Profile: Daniëlle van Dorth, Sadaf Soloukey, Pieter Kruizinga, Krishnapriya Venugopal, Aurélien Delphin, Dirk H J Poot, Thomas Christen, Marion Smits, Jeroen de Bresser, Juan A Hernandez-Tamames, Matthias J P van Osch

Förderung

  • Dutch Research Council (NWO)
  • Medical Delta
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Zitieren

APA

van Dorth, D., Alafandi, A., Soloukey, S., Kruizinga, P., Venugopal, K., Delphin, A., Poot, D. H. J., Christen, T., Smits, M., de Bresser, J., Hernandez-Tamames, J. A., & van Osch, M. J. P. (2025). The Road to a Realistic 3D Model for Estimating R 2 and R 2 * Relaxation Versus Gd‐DTPA Concentration in Whole Blood and Brain Tumor Vasculature. NMR in Biomedicine. https://doi.org/10.1002/nbm.5308

Vancouver

van Dorth D, Alafandi A, Soloukey S, Kruizinga P, Venugopal K, Delphin A, et al. The Road to a Realistic 3D Model for Estimating R 2 and R 2 * Relaxation Versus Gd‐DTPA Concentration in Whole Blood and Brain Tumor Vasculature. NMR in Biomedicine. 2025. doi:10.1002/nbm.5308

BibTeX
@article{vanDorth2025,
  author = {van Dorth, Daniëlle and Alafandi, Ahmad and Soloukey, Sadaf and Kruizinga, Pieter and Venugopal, Krishnapriya and Delphin, Aurélien and Poot, Dirk H J and Christen, Thomas and Smits, Marion and de Bresser, Jeroen and Hernandez-Tamames, Juan A and van Osch, Matthias J P},
  title = {The Road to a Realistic 3D Model for Estimating R 2 and R 2 * Relaxation Versus Gd‐DTPA Concentration in Whole Blood and Brain Tumor Vasculature},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.5308}
}
Kostenlos starten →