Dynamic glucose‐enhanced MRI of gliomas: A preliminary clinical application
NMR in Biomedicine · 2025-01 · 38 (1)
DOI: 10.1002/nbm.5265 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 05.11.2024. Verfasst von Jianhua Mo und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China. Hauptthemen laut MEDLINE: Glioma, Magnetic Resonance Imaging, Glucose, Brain Neoplasms. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, Swedish Cancer Society, Swedish Brain Foundation.
Abstract (Originalsprache)
The study aimed to investigate the feasibility of dynamic glucose‐enhanced (DGE) MRI technology in the clinical application of glioma. Twenty patients with glioma were examined using a preoperative DGE‐MRI protocol before clinical intervention. A brief hyperglycemic state was achieved by injecting 50 mL of 50% w/w D‐glucose intravenously during the DGE imaging. The total acquisition time for the DGE was 15 min. Area‐under‐the‐curve (AUC) images were calculated using the DGE images. AUC 2–7min values of the glioma core, margin area, edema area, and contralateral brain parenchyma were compared using Mann–Whitney U tests. Overall, gray and white matter areas in the AUC images showed relatively low DGE signal change and bilateral symmetry. However, the tumor cores displayed a significant hyperintensity. A high DGE signal change was also seen in the necrotic, cystic, and cerebrospinal areas. These results show that DGE MRI is a feasible technique for the study of brain tumors as part of a clinical exam. Importantly, DGE MRI showed enhancement in areas confirmed histopathologically as tumors, whereas Gd T1w MRI did not show any enhancement in this area. Since the D‐glucose molecule is smaller than Gd‐based contrast agents, DGE MRI may be more sensitive to subtle blood–brain barrier disruptions, thus potentially providing early information about possible malignancy. These findings provide a new perspective for the further exploration and analysis of D‐glucose uptake in brain tumors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China.
- Icahn School of Medicine at Mount Sinai, BioMedical Engineering and Imaging Institute, New York, New York, USA.
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- Department of Medical Radiation Physics, Lund University, Lund, Sweden.
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
- Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
ORCID-Profile: Linda Knutsson
Förderung
- NIBIB NIH HHS
- Swedish Cancer Society
- Swedish Brain Foundation
- Swedish Research Council
- NIH HHS
- Southern Medical University Clinical Research Project
- The Scientific Research Funding Project of the Nanfang Medical Imaging Alliance
- Natural Science Fundation of Guangdong Province
Zitieren
APA
Mo, J., Xu, X., Ma, A., Lu, M., Wang, X., Rui, Q., Zhu, J., Wen, H., Lin, G., Knutsson, L., van Zijl, P., & Wen, Z. (2025). Dynamic glucose‐enhanced MRI of gliomas: A preliminary clinical application. NMR in Biomedicine, 38(1). https://doi.org/10.1002/nbm.5265
Vancouver
Mo J, Xu X, Ma A, Lu M, Wang X, Rui Q, et al. Dynamic glucose‐enhanced MRI of gliomas: A preliminary clinical application. NMR in Biomedicine. 2025;38(1). doi:10.1002/nbm.5265
BibTeX
@article{Mo2025,
author = {Mo, Jianhua and Xu, Xiang and Ma, Andong and Lu, Mingjun and Wang, Xianlong and Rui, Qihong and Zhu, Jianbin and Wen, Haitao and Lin, Genyun and Knutsson, Linda and van Zijl, Peter and Wen, Zhibo},
title = {Dynamic glucose‐enhanced MRI of gliomas: A preliminary clinical application},
journal = {NMR in Biomedicine},
year = {2025},
volume = {38},
number = {1},
doi = {10.1002/nbm.5265}
}
EUVIMED