EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Repeatability of alkaline inorganic phosphate quantification in the skeletal muscle using 31 P‐magnetic resonance spectroscopy at 3 T

Alexs A Matias, Corinna F Serviente, Stephen T Decker, Muhammet Enes Erol, Gaia Giuriato, Yann Le Fur, Rajakumar Nagarajan, David Bendahan, Gwenael Layec

NMR in Biomedicine · 2024

DOI: 10.1002/nbm.5255 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Alexs A Matias und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology, University of Massachusetts at Amherst, Amherst, MA, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Spectroscopy, Phosphates, Muscle, Skeletal. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, National Heart, Lung, and Blood Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The detection of a secondary inorganic phosphate (Pi) resonance, a possible marker of mitochondrial content in vivo, using phosphorus magnetic resonance spectroscopy ( 31 P‐MRS), poses technical challenges at 3 Tesla (T). Overcoming these challenges is imperative for the integration of this biomarker into clinical research. To evaluate the repeatability and reliability of measuring resting skeletal muscle alkaline Pi (Pi alk ) using with 31 P‐MRS at 3 T. After an initial set of experiments on five subjects to optimize the sequence, resting 31 P‐MRS of the quadriceps muscles were acquired on two visits (~4 days apart) using an intra‐subjects design, from 13 sedentary to moderately active young male and female adults (22 ± 3 years old) within a whole‐body 3 T MR system. Measurement variability attributed to changes in coil position, shimming procedure, and spectral analysis were quantified. 31 P‐MRS data were acquired with a 31 P/‐proton ( 1 H) dual‐tuned surface coil positioned on the quadriceps using a pulse‐acquire sequence. Test–retest absolute and relative repeatability was analyzed using the coefficient of variation (CV) and intra‐class correlation coefficients (ICC), respectively. After sequence parameter optimization, Pi alk demonstrated high intra‐subject repeatability (CV: 10.6 ± 5.4%, ICC: 0.80). Proximo‐distal change in coil position along the length of the quadriceps introduced Pi alk quantitation variability (CV: 28 ± 5%), due to magnetic field inhomogeneity with more distal coil locations. In contrast, Pi alk measurement variability due to repeated shims from the same muscle volume (0.40 ± 0.09mM; CV: 6.6%), and automated spectral processing (0.37 ± 0.01mM; CV: 2.3%), was minor. The quantification of Pi alk in skeletal muscle via surface coil 31P‐MRS at 3 T demonstrated excellent reproducibility. However, caution is advised against placing the coil at the distal part of the quadriceps to mitigate shimming inhomogeneity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance SpectroscopyPhosphatesMuscle, SkeletalHumansMaleFemaleReproducibility of ResultsYoung AdultAdultPhosphorus IsotopesAlkalies

Stichwörter der Autor:innen

31P‐MRSmitochondriamitochondrial biomarkermuscle MR spectroscopymuscle energeticsrepeatability

Substanzen

PhosphatesPhosphorus IsotopesAlkalies

Autor:innen und Institutionen

  • Department of Kinesiology, University of Massachusetts at Amherst, Amherst, MA, USA.
  • Diabetes & Metabolism Research Center, University of Utah, Salt Lake City, UT, USA.
  • The Institute for Applied Life Sciences, University of Massachusetts at Amherst, Amherst, MA, USA.
  • School of Health and Kinesiology, University of Nebraska at Omaha, Omaha, NE, USA.
  • Department of Neuroscience, Biomedicine, and Movement Science, University of Verona, Verona, Italy.
  • Department of Surgical, Medical and Dental, University of Modena and Reggio Emilia, Modena, Italy.

Förderung

  • NHLBI NIH HHS
  • National Heart, Lung, and Blood Institute

Zitieren

APA

Matias, A. A., Serviente, C. F., Decker, S. T., Erol, M. E., Giuriato, G., Le Fur, Y., Nagarajan, R., Bendahan, D., & Layec, G. (2024). Repeatability of alkaline inorganic phosphate quantification in the skeletal muscle using 31 P‐magnetic resonance spectroscopy at 3 T. NMR in Biomedicine. https://doi.org/10.1002/nbm.5255

Vancouver

Matias AA, Serviente CF, Decker ST, Erol ME, Giuriato G, Le Fur Y, et al. Repeatability of alkaline inorganic phosphate quantification in the skeletal muscle using 31 P‐magnetic resonance spectroscopy at 3 T. NMR in Biomedicine. 2024. doi:10.1002/nbm.5255

BibTeX
@article{Matias2024,
  author = {Matias, Alexs A and Serviente, Corinna F and Decker, Stephen T and Erol, Muhammet Enes and Giuriato, Gaia and Le Fur, Yann and Nagarajan, Rajakumar and Bendahan, David and Layec, Gwenael},
  title = {Repeatability of alkaline inorganic phosphate quantification in the skeletal muscle using 31 P‐magnetic resonance spectroscopy at 3 T},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5255}
}
Kostenlos starten →