EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Post mortem analysis of hepatic volume and lipid content by magnetic resonance imaging and spectroscopy in fixed murine neonates

Marc Jonuscheit iD, Celina Uhlemeyer iD, Benedict Korzekwa, Marten Schouwink, Soner Öner-Sieben, Regina Ensenauer, Michael Roden, Bengt-Frederik Belgardt, Vera B Schrauwen-Hinderling

NMR in Biomedicine · 2024

DOI: 10.1002/nbm.5140 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Marc Jonuscheit und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Clinical Diabetology, German Diabetes Center, Leibniz Institute for Diabetes Research at Heinrich Heine University Düsseldorf, Düsseldo…. Hauptthemen laut MEDLINE: Liver, Magnetic Resonance Imaging, Animals, Newborn. Die Arbeit nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: German Center for Diabetes Research, German Diabetes Center, Ministry of Culture and Science of the State of North Rhine Westphalia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Maternal obesity and hyperglycemia are linked to an elevated risk for obesity, diabetes, and steatotic liver disease in the adult offspring. To establish and validate a noninvasive workflow for perinatal metabolic phenotyping, fixed neonates of common mouse strains were analyzed postmortem via magnetic resonance imaging (MRI)/magnetic resonance spectroscopy (MRS) to assess liver volume and hepatic lipid (HL) content. The key advantage of nondestructive MRI/MRS analysis is the possibility of further tissue analyses, such as immunohistochemistry, RNA extraction, and even proteomics, maximizing the data that can be gained per individual and therefore facilitating comprehensive correlation analyses. This study employed an MRI and 1 H‐MRS workflow to measure liver volume and HL content in 65 paraformaldehyde‐fixed murine neonates at 11.7 T. Liver volume was obtained using semiautomatic segmentation of MRI acquired by a RARE sequence with 0.5‐mm slice thickness. HL content was measured by a STEAM sequence, applied with and without water suppression. T 1 and T 2 relaxation times of lipids and water were measured for respective correction of signal intensity. The HL content, given as CH 2 /(CH 2 + H 2 O), was calculated, and the intrasession repeatability of the method was tested. The established workflow yielded robust results with a variation of ~3% in repeated measurements for HL content determination. HL content measurements were further validated by correlation analysis with biochemically assessed triglyceride contents ( R 2 = 0.795) that were measured in littermates. In addition, image quality also allowed quantification of subcutaneous adipose tissue and stomach diameter. The highest HL content was measured in C57Bl/6N (4.2%) and the largest liver volume and stomach diameter in CBA (53.1 mm 3 and 6.73 mm) and NMRI (51.4 mm 3 and 5.96 mm) neonates, which also had the most subcutaneous adipose tissue. The observed effects were independent of sex and litter size. In conclusion, we have successfully tested and validated a robust MRI/MRS workflow that allows assessment of morphology and HL content and further enables paraformaldehyde‐fixed tissue‐compatible subsequent analyses in murine neonates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverMagnetic Resonance ImagingAnimals, NewbornAnimalsMice, Inbred C57BLLipidsMiceOrgan SizeMagnetic Resonance SpectroscopyFemaleReproducibility of ResultsTissue FixationAutopsyMale

Stichwörter der Autor:innen

hepatic lipid contentliver volumemagnetic resonance spectroscopymouseneonatesoffspringperinataltriglyceride assay

Substanzen

Lipids

Autor:innen und Institutionen

  • Institute for Clinical Diabetology, German Diabetes Center, Leibniz Institute for Diabetes Research at Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
  • German Center for Diabetes Research (DZD e.V.), München-Neuherberg, Germany.
  • Institute for Vascular and Islet Cell Biology, German Diabetes Center, Leibniz Institute for Diabetes Research at Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
  • University Children's Hospital, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
  • Institute of Child Nutrition, Max Rubner-Institut, Federal Research Institute of Nutrition and Food, Karlsruhe, Germany.
  • Department of Endocrinology and Diabetology, Medical Faculty and University Hospital Düsseldorf, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.

ORCID-Profile: Marc Jonuscheit, Celina Uhlemeyer

Förderung

  • German Center for Diabetes Research
  • German Diabetes Center
  • Ministry of Culture and Science of the State of North Rhine Westphalia
  • German Federal Ministry of Health
  • Federal Ministry of Education and Research
  • Eickelberg Foundation
  • German Research Foundation
  • HORIZON EUROPE Framework Programme

Zitieren

APA

Jonuscheit, M., Uhlemeyer, C., Korzekwa, B., Schouwink, M., Öner-Sieben, S., Ensenauer, R., Roden, M., Belgardt, B. F., & Schrauwen-Hinderling, V. B. (2024). Post mortem analysis of hepatic volume and lipid content by magnetic resonance imaging and spectroscopy in fixed murine neonates. NMR in Biomedicine. https://doi.org/10.1002/nbm.5140

Vancouver

Jonuscheit M, Uhlemeyer C, Korzekwa B, Schouwink M, Öner-Sieben S, Ensenauer R, et al. Post mortem analysis of hepatic volume and lipid content by magnetic resonance imaging and spectroscopy in fixed murine neonates. NMR in Biomedicine. 2024. doi:10.1002/nbm.5140

BibTeX
@article{Jonuscheit2024,
  author = {Jonuscheit, Marc and Uhlemeyer, Celina and Korzekwa, Benedict and Schouwink, Marten and Öner-Sieben, Soner and Ensenauer, Regina and Roden, Michael and Belgardt, Bengt-Frederik and Schrauwen-Hinderling, Vera B},
  title = {Post mortem analysis of hepatic volume and lipid content by magnetic resonance imaging and spectroscopy in fixed murine neonates},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5140}
}
Kostenlos starten →