Incorporation of view sharing and KWIC filtering into GRASP‐Pro improves spatial resolution of single‐shot, multi‐TI, late gadolinium enhancement MRI

Mingyue Zhao, Daming Shen iD, Lexiaozi Fan, Kyungpyo Hong, Li Feng iD, Brandon C Benefield, Bradley D Allen, Daniel C Lee, Daniel Kim iD

NMR in Biomedicine · 2024

DOI: 10.1002/nbm.5059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Mingyue Zhao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Contrast Media, Gadolinium. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIH HHS, NHLBI NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

While single‐shot late gadolinium enhancement (LGE) is useful for imaging patients with arrhythmia and/or dyspnea, it produces low spatial resolution. One approach to improve spatial resolution is to accelerate data acquisition using compressed sensing (CS). Our previous work described a single‐shot, multi‐inversion time (TI) LGE pulse sequence using radial k ‐space sampling and CS, but over‐regularization resulted in significant image blurring that muted the benefits of data acceleration. The purpose of the present study was to improve the spatial resolution of the single‐shot, multi‐TI LGE pulse sequence by incorporating view sharing (VS) and k ‐space weighted contrast (KWIC) filtering into a GRASP‐Pro reconstruction. In 24 patients (mean age = 61 ± 16 years; 9/15 females/males), we compared the performance of our improved multi‐TI LGE and standard multi‐TI LGE, where clinical standard LGE was used as a reference. Two clinical raters independently graded multi‐TI images and clinical LGE images visually on a five‐point Likert scale (1, nondiagnostic; 3, clinically acceptable; 5, best) for three categories: the conspicuity of myocardium or scar, artifact, and noise. The summed visual score (SVS) was defined as the sum of the three scores. Myocardial scar volume was quantified using the full‐width at half‐maximum method. The SVS was not significantly different between clinical breath‐holding LGE (median 13.5, IQR 1.3) and multi‐TI LGE (median 12.5, IQR 1.6) ( P = 0.068). The myocardial scar volumes measured from clinical standard LGE and multi‐TI LGE were strongly correlated (coefficient of determination, R 2 = 0.99) and in good agreement (mean difference = 0.11%, lower limit of the agreement = −2.13%, upper limit of the agreement = 2.34%). The inter‐rater agreement in myocardial scar volume quantification was strong (intraclass correlation coefficient = 0.79). The incorporation of VS and KWIC into GRASP‐Pro improved spatial resolution. Our improved 25‐fold accelerated, single‐shot LGE sequence produces clinically acceptable image quality, multi‐TI reconstruction, and accurate myocardial scar volume quantification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaGadoliniumMaleFemaleHumansMiddle AgedAgedCicatrixMagnetic Resonance ImagingMyocardium

Stichwörter der Autor:innen

balanced steady-state free precession (b-SSFP)compressed sensing (CS)inversion recovery (IR)inversion time (TI)k-space weighted contrast filtering (KWIC)late gadolinium enhancement (LGE)view sharing (VS)

Substanzen

Contrast MediaGadolinium

Autor:innen und Institutionen

  • Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.
  • Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA.
  • General Electric HealthCare, Waukesha, Wisconsin, USA.
  • Center for Advanced Imaging Innovation and Research (CAI2R), New York University Grossman School of Medicine, New York, New York, USA.
  • Division of Cardiology, Internal Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.

ORCID-Profile: Daming Shen, Li Feng, Daniel Kim

Förderung

  • NIH HHS
  • NHLBI NIH HHS
  • NIBIB NIH HHS
  • American Heart Association-American Stroke Association
  • National Institutes of Health
  • American Heart Association

Zitieren

APA

Zhao, M., Shen, D., Fan, L., Hong, K., Feng, L., Benefield, B. C., Allen, B. D., Lee, D. C., & Kim, D. (2024). Incorporation of view sharing and KWIC filtering into GRASP‐Pro improves spatial resolution of single‐shot, multi‐TI, late gadolinium enhancement MRI. NMR in Biomedicine. https://doi.org/10.1002/nbm.5059

Vancouver

Zhao M, Shen D, Fan L, Hong K, Feng L, Benefield BC, et al. Incorporation of view sharing and KWIC filtering into GRASP‐Pro improves spatial resolution of single‐shot, multi‐TI, late gadolinium enhancement MRI. NMR in Biomedicine. 2024. doi:10.1002/nbm.5059

BibTeX
@article{Zhao2024,
  author = {Zhao, Mingyue and Shen, Daming and Fan, Lexiaozi and Hong, Kyungpyo and Feng, Li and Benefield, Brandon C and Allen, Bradley D and Lee, Daniel C and Kim, Daniel},
  title = {Incorporation of view sharing and KWIC filtering into GRASP‐Pro improves spatial resolution of single‐shot, multi‐TI, late gadolinium enhancement MRI},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5059}
}
Kostenlos starten →