Water diffusion and T 2 quantification in transient‐state MRI: the effect of RF pulse sequence
NMR in Biomedicine · 2024
DOI: 10.1002/nbm.5044 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Miha Fuderer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Radiotherapy, Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nederlandse Organisatie voor Wetenschappelijk Onderzoek.
Abstract (Originalsprache)
In quantitative measurement of the value of tissues, the diffusion of water molecules has been recognized as a confounder. This is most notably so for transient‐state quantitative mapping techniques, which allow simultaneous estimation of and . In prior work, apparently conflicting conclusions are presented on the level of diffusion‐induced bias on the T 2 estimate. So far there is a lack of studies on the effect of the RF pulse angle sequence on the level of diffusion‐induced bias. In this work, we show that the specific transient‐state RF pulse sequence has a large effect on this level of bias. In particular, the bias level is strongly influenced by the mean value of the RF pulse angles. Also, for realistic values of the spoiling gradient area, we infer that the diffusion‐induced bias is negligible for non‐liquid human tissues; yet, for phantoms, the effect can be substantial (15% of the true value) for some RF pulse sequences. This should be taken into account in validation procedures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiotherapy, Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands.
ORCID-Profile: Miha Fuderer, Oscar van der Heide, Hongyan Liu
Förderung
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Zitieren
APA
Fuderer, M., van der Heide, O., Liu, H., van den Berg, C. A. T., & Sbrizzi, A. (2024). Water diffusion and T 2 quantification in transient‐state MRI: the effect of RF pulse sequence. NMR in Biomedicine. https://doi.org/10.1002/nbm.5044
Vancouver
Fuderer M, van der Heide O, Liu H, van den Berg CAT, Sbrizzi A. Water diffusion and T 2 quantification in transient‐state MRI: the effect of RF pulse sequence. NMR in Biomedicine. 2024. doi:10.1002/nbm.5044
BibTeX
@article{Fuderer2024,
author = {Fuderer, Miha and van der Heide, Oscar and Liu, Hongyan and van den Berg, Cornelis A T and Sbrizzi, Alessandro},
title = {Water diffusion and T 2 quantification in transient‐state MRI: the effect of RF pulse sequence},
journal = {NMR in Biomedicine},
year = {2024},
doi = {10.1002/nbm.5044}
}
EUVIMED