Numerical simulation‐based assessment of pH‐sensitive chemical exchange saturation transfer MRI quantification accuracy across field strengths

Phillip Zhe Sun

NMR in Biomedicine · 2023

DOI: 10.1002/nbm.5000 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2023. Verfasst von Phillip Zhe Sun. Beteiligte Einrichtung: Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: I3 MedTech Award from the Emory School of Medicine and through the Georgia CTSA NIH award, National Institute of Health, NIAMS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chemical exchange saturation transfer (CEST) MRI detects dilute labile protons via their exchange with bulk water, conferring pH sensitivity. Based on published exchange and relaxation properties, a 19‐pool simulation was used to model the brain pH‐dependent CEST effect and assess the accuracy of quantitative CEST (qCEST) analysis across magnetic field strengths under typical scan conditions. First, the optimal B 1 amplitude was determined by maximizing pH‐sensitive amide proton transfer (APT) contrast under the equilibrium condition. Apparent and quasi‐steady‐state (QUASS) CEST effects were then derived under the optimal B 1 amplitude as functions of pH, RF saturation duration, relaxation delay, Ernst flip angle, and field strength. Finally, CEST effects, particularly the APT signal, were isolated with spinlock model‐based Z‐spectral fitting to evaluate the accuracy and consistency of CEST quantification. Our data showed that QUASS reconstruction significantly improved the consistency between simulated and equilibrium Z‐spectra. The residual difference between QUASS and equilibrium CEST Z‐spectra was, on average, 30 times less than that of the apparent CEST Z‐spectra across field strengths, saturation, and repetition times. Also, the spinlock fitting of the QUASS CEST effect significantly reduced the residual errors 9‐fold. Furthermore, the isolated APT amplitude from QUASS reconstruction was consistent and higher than the apparent CEST analysis under nonequilibrium conditions. To summarize, this study confirmed that QUASS reconstruction facilitates accurate determination of the CEST system under different scan protocols across field strengths, with the potential to help standardize CEST quantification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingHydrogen-Ion ConcentrationComputer SimulationHumansBrainPhantoms, ImagingProtons

Stichwörter der Autor:innen

Bloch-McConnell equationsamide proton transferchemical exchange saturation transferquasi-steady-state analysis

Substanzen

Protons

Autor:innen und Institutionen

  • Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, Georgia, USA.
  • Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA.

Förderung

  • I3 MedTech Award from the Emory School of Medicine and through the Georgia CTSA NIH award
  • National Institute of Health
  • NIAMS NIH HHS
  • Emory University Synergy Award
  • NINDS NIH HHS
  • National Center for Advancing Translational Sciences

Zitieren

APA

Sun, P. Z. (2023). Numerical simulation‐based assessment of pH‐sensitive chemical exchange saturation transfer MRI quantification accuracy across field strengths. NMR in Biomedicine. https://doi.org/10.1002/nbm.5000

Vancouver

Sun PZ. Numerical simulation‐based assessment of pH‐sensitive chemical exchange saturation transfer MRI quantification accuracy across field strengths. NMR in Biomedicine. 2023. doi:10.1002/nbm.5000

BibTeX
@article{Sun2023,
  author = {Sun, Phillip Zhe},
  title = {Numerical simulation‐based assessment of pH‐sensitive chemical exchange saturation transfer MRI quantification accuracy across field strengths},
  journal = {NMR in Biomedicine},
  year = {2023},
  doi = {10.1002/nbm.5000}
}