Why are continent catheterizable channels continent? A stomal pressure profilometry feasibility study
Neurourology and Urodynamics · 2024
DOI: 10.1002/nau.25546 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neurourology and Urodynamics, 2024. Verfasst von Coen H H Christiaans und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, UMC Utrecht, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Feasibility Studies, Urodynamics, Urinary Catheterization, Pressure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
A continent catheterizable channel (CCC) may be a solution for patients with impaired bladder emptying and difficult transurethral access. Leakage of the CCC is a common complication. To prevent leakage, the pressure in the CCC has to be higher than the reservoir (bladder/pouch) pressure in at least one location. It has not been clearly defined through which mechanism(s) the CCC achieves continence. In this feasibility study, we measured the CCC pressure profile in adult patients with various types of CCC's with and without stomal leakage.
Methods
Adult patients with a CCC on a (augmented) bladder or pouch who underwent a urodynamic investigation between January and March 2023 were included. Next to the standard urodynamic investigation, a continuous stomal pressure measurement (CSP) and stomal pressure profilometry with empty bladder (SPP‐1) and with filled bladder (SPP‐2) of the CCC were performed.
Results
A total of 17 patients were included. It was technically possible to perform SPP‐1 and SPP‐2 in all patients, and to measure the CSP in 16/17 patients. The median maximum stomal pressures in SPP‐1 and SPP‐2 were 112 (interquartile range [IQR], 76–140) cmH2O and 120 (IQR, 92–140) cmH2O, respectively. Nine patients had stomal leakage during the urodynamic investigation. In five patients, the detrusor leak point pressure (dLPP) was low (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, UMC Utrecht, Utrecht, The Netherlands.
ORCID-Profile: Coen H H Christiaans, Pepijn D Polm, Thomas R F van Steenbergen, Michel I A Wyndaele, Laetitia M O de Kort
Zitieren
APA
Christiaans, C. H. H., Polm, P. D., van Steenbergen, T. R. F., Wyndaele, M. I. A., & de Kort, L. M. O. (2024). Why are continent catheterizable channels continent? A stomal pressure profilometry feasibility study. Neurourology and Urodynamics. https://doi.org/10.1002/nau.25546
Vancouver
Christiaans CHH, Polm PD, van Steenbergen TRF, Wyndaele MIA, de Kort LMO. Why are continent catheterizable channels continent? A stomal pressure profilometry feasibility study. Neurourology and Urodynamics. 2024. doi:10.1002/nau.25546
BibTeX
@article{Christiaans2024,
author = {Christiaans, Coen H H and Polm, Pepijn D and van Steenbergen, Thomas R F and Wyndaele, Michel I A and de Kort, Laetitia M O},
title = {Why are continent catheterizable channels continent? A stomal pressure profilometry feasibility study},
journal = {Neurourology and Urodynamics},
year = {2024},
doi = {10.1002/nau.25546}
}
EUVIMED