Quantitative Ultrasound Analysis of Muscle Reinnervation Following Anterior Interosseous Nerve‐To‐Ulnar Motor Branch Supercharged End‐To‐Side Transfer Surgery: A Preliminary Study
Muscle & Nerve · 2026-12 · 74 (6) · 1587-1595
DOI: 10.1002/mus.70407 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muscle & Nerve, online erschienen am 25.09.2026. Verfasst von Rémy Liechti und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Hand Surgery, Inselspital, University Hospital of Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Muscle, Skeletal, Ulnar Nerve, Nerve Transfer, Nerve Regeneration. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction/Aims Routine assessment of muscle reinnervation primarily relies on clinical and electromyographic evaluation. The aim of this preliminary study was to evaluate sensitivity of quantitative ultrasound analysis for monitoring intrinsic hand muscle recovery following anterior interosseous nerve (AIN)‐to‐ulnar motor branch supercharged end‐to‐side (SETS) transfer.
Methods
Eight patients (five male, three female; mean age 54.5 years, range 10–80) underwent anterior ulnar nerve transposition with AIN‐to‐ulnar motor branch SETS transfer. High‐resolution ultrasound assessed the first dorsal interosseous (FDI) and hypothenar muscles pre‐ and postoperatively using quantitative grayscale and cross‐sectional thickness (CST) analysis. Functional outcomes included key pinch and grip strength.
Results
Preoperatively, affected FDI and hypothenar muscles exhibited significantly higher grayscale and lower CST values compared with the contralateral side. Following surgery, this difference decreased significantly in both muscle groups (FDI: mean difference [MD] −19.9, 95% CI −33.5 to −6.3; p = 0.013; hypothenar: MD −21.2, 95% CI −32.1 to −10.3; p = 0.006). CST measurements improved in the FDI muscle (MD −7.1 mm, 95% CI −11.3 to −2.9; p = 0.009), while there was no significant CST change in the hypothenar muscle (MD −2.3 mm, 95% CI −4.9 to 0.4; p = 0.081). There was a significant correlation between FDI muscle grayscale values and key pinch strength ( R 2 = 0.31), whereas hypothenar echogenicity showed no correlation with grip strength ( R 2 = 0.0001).
Discussion
This preliminary study suggests that quantitative ultrasound of intrinsic hand muscles appears sensitive and can detect structural changes during reinnervation following AIN‐to‐ulnar motor branch SETS transfer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic and Hand Surgery, Inselspital, University Hospital of Bern, Bern, Switzerland.
ORCID-Profile: Rémy Liechti, Esther Vögelin
Zitieren
APA
Liechti, R., & Vögelin, E. (2026). Quantitative Ultrasound Analysis of Muscle Reinnervation Following Anterior Interosseous Nerve‐To‐Ulnar Motor Branch Supercharged End‐To‐Side Transfer Surgery: A Preliminary Study. Muscle & Nerve, 74(6), 1587-1595. https://doi.org/10.1002/mus.70407
Vancouver
Liechti R, Vögelin E. Quantitative Ultrasound Analysis of Muscle Reinnervation Following Anterior Interosseous Nerve‐To‐Ulnar Motor Branch Supercharged End‐To‐Side Transfer Surgery: A Preliminary Study. Muscle & Nerve. 2026;74(6):1587-1595. doi:10.1002/mus.70407
BibTeX
@article{Liechti2026,
author = {Liechti, Rémy and Vögelin, Esther},
title = {Quantitative Ultrasound Analysis of Muscle Reinnervation Following Anterior Interosseous Nerve‐To‐Ulnar Motor Branch Supercharged End‐To‐Side Transfer Surgery: A Preliminary Study},
journal = {Muscle & Nerve},
year = {2026},
volume = {74},
number = {6},
pages = {1587--1595},
doi = {10.1002/mus.70407}
}