Conservative Safety Assessment of a Nitinol Microhook Coaptation Device on Intact Nerve
Muscle & Nerve · 2026-09 · 74 (3) · 720-727
DOI: 10.1002/mus.70346 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muscle & Nerve, online erschienen am 14.07.2026. Verfasst von Jonathan Isaacs und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Hand Surgery, Department of Orthopaedic Surgery, Virginia Commonwealth University Health System, Richmond, Virginia, USA. Hauptthemen laut MEDLINE: Alloys, Tibial Nerve. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: BCT, Bat Conservation Trust.
Abstract (Originalsprache)
Introduction/Aims Nerve Tape is a novel nerve coaptation device that eliminates the technical challenges of microsuturing. The device incorporates tissue‐engaging Nitinol microhooks within a flexible backing of decellularized porcine small intestine submucosa (SIS). Preclinical nerve injury models have demonstrated device safety and effective promotion of regeneration and recovery. Here, we further assess the impact of the device's components on nerve tissue and function, using a highly conservative model in which the device is applied to intact nerves.
Methods
Nerve Tape, sutures, or SIS were applied to rabbit tibial nerves in a manner simulating transection repairs but leaving the nerves intact. After three months, “repaired” nerves and target gastrocnemius muscles along with contralateral control nerves and muscles were evaluated for perineural scarring, inflammation, and function utilizing gross inspection, morphology measurements, electrophysiology, and histology.
Results
Analysis of endpoint data, including muscle mass/girth, nerve compound action potential (NCAP) amplitude, conduction velocity, axon counts, and g‐ratio revealed no significant differences between experimental or control groups (distal axon count/g‐ratio: Nerve Tape 6546 ± 2300, 0.647 ± 0.04; Suture 7979 ± 666, 0.664 ± 0.033; SIS 7537 ± 2117, 0.689 ± 0.02; control 6158 ± 1958, 0.631 ± 0.02). Gross adhesion thickness at the treatment site was higher in the Suture group versus the Nerve Tape group. Granulomas and neovascularization were most pronounced in the Suture group. Macrophage/lymphocyte/plasma cell presence was associated with SIS material. No additional tissue response was observed in response to Nitinol components.
Discussion
Nerve Tape's SIS and Nitinol microhook design maintained the health of an intact nerve with sequelae comparable to sutures or SIS without microhooks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Hand Surgery, Department of Orthopaedic Surgery, Virginia Commonwealth University Health System, Richmond, Virginia, USA.
- William & Mary, Williamsburg, Virginia, USA.
- Department of Pathology, Virginia Commonwealth University Health System, Richmond, Virginia, USA.
- Department of Plastic Surgery, University Medical Center Utrecht, Utrecht, the Netherlands.
ORCID-Profile: Hope T Richard
Förderung
- BCT
- Bat Conservation Trust
Zitieren
APA
Isaacs, J., Bendale, G. S., Gomatam, A., Richard, H. T., Reiter, C., Savsani, K., Mazur, M., Allen, T., & Clough, N. (2026). Conservative Safety Assessment of a Nitinol Microhook Coaptation Device on Intact Nerve. Muscle & Nerve, 74(3), 720-727. https://doi.org/10.1002/mus.70346
Vancouver
Isaacs J, Bendale GS, Gomatam A, Richard HT, Reiter C, Savsani K, et al. Conservative Safety Assessment of a Nitinol Microhook Coaptation Device on Intact Nerve. Muscle & Nerve. 2026;74(3):720-727. doi:10.1002/mus.70346
BibTeX
@article{Isaacs2026,
author = {Isaacs, Jonathan and Bendale, Geetanjali S and Gomatam, Ananya and Richard, Hope T and Reiter, Charles and Savsani, Kush and Mazur, Marc and Allen, Taylor and Clough, Noah},
title = {Conservative Safety Assessment of a Nitinol Microhook Coaptation Device on Intact Nerve},
journal = {Muscle & Nerve},
year = {2026},
volume = {74},
number = {3},
pages = {720--727},
doi = {10.1002/mus.70346}
}
EUVIMED