Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation
Muscle & Nerve · 2026
DOI: 10.1002/mus.70285 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muscle & Nerve, 2026. Verfasst von Yajing Ye und 2 weiteren Autor:innen. Beteiligte Einrichtung: Neuromuscular Center & EMG Laboratory, the Neurological Institute, University Hospitals Cleveland Medical Center, Case Western Reserve University Sch…. Hauptthemen laut MEDLINE: Median Nerve. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction/Aims Conduction block (CB) at non‐entrapment sites is an important electrodiagnostic (EDX) feature supporting acquired demyelinating neuropathies. However, anatomical variation may produce pseudoconduction block, mimicking true CB. After encountering a patient with median nerve pseudoconduction block due to anatomical variation, we aimed to assess the frequency of this variation, its impact on EDX interpretation, and the role of neuromuscular ultrasound (NMUS) in improving diagnostic accuracy.
Methods
We describe an index patient with median nerve pseudoconduction block in the forearm caused by anatomical variation, confirmed by ultrasound. We then retrospectively reviewed upper limb NMUS performed by a single EDX medicine specialist at University Hospitals Cleveland Medical Center. At the antecubital fossa, the distance between the midpoint of the brachial artery and the midpoint of the median nerve was measured. Available EDX values were reviewed for ultrasounds with marked nerve‐artery separation.
Results
Sixty‐eight patients were included. In all patients, the median nerve lay medial to the brachial artery (range: 2.5–26 mm). Seven patients (10.3%) had nerve‐artery separation greater than 12.5 mm. Of these, five had available EDX data for retrospective review and three (60%) reported either complete or partial CB.
Discussion
True CB suggests significant pathology. NMUS can help distinguish pseudoconduction block from true CB and prevent misdiagnosis. When pseudoconduction block of the median nerve in the forearm is suspected, stimulation 15–25 mm medial to the brachial artery pulse, or slightly more medial and proximal (between the bicep tendon and brachialis muscle) may improve accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neuromuscular Center & EMG Laboratory, the Neurological Institute, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA.
- Department of Neurology, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio, USA.
ORCID-Profile: Yajing Ye, Bashar Katirji, Robert D Adams
Zitieren
APA
Ye, Y., Katirji, B., & Adams, R. D. (2026). Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation. Muscle & Nerve. https://doi.org/10.1002/mus.70285
Vancouver
Ye Y, Katirji B, Adams RD. Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation. Muscle & Nerve. 2026. doi:10.1002/mus.70285
BibTeX
@article{Ye2026,
author = {Ye, Yajing and Katirji, Bashar and Adams, Robert D},
title = {Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation},
journal = {Muscle & Nerve},
year = {2026},
doi = {10.1002/mus.70285}
}
EUVIMED