Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation

Yajing Ye iD, Bashar Katirji iD, Robert D Adams iD

Muscle & Nerve · 2026

DOI: 10.1002/mus.70285 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Muscle & Nerve, 2026. Verfasst von Yajing Ye und 2 weiteren Autor:innen. Beteiligte Einrichtung: Neuromuscular Center & EMG Laboratory, the Neurological Institute, University Hospitals Cleveland Medical Center, Case Western Reserve University Sch…. Hauptthemen laut MEDLINE: Median Nerve. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Aims Conduction block (CB) at non‐entrapment sites is an important electrodiagnostic (EDX) feature supporting acquired demyelinating neuropathies. However, anatomical variation may produce pseudoconduction block, mimicking true CB. After encountering a patient with median nerve pseudoconduction block due to anatomical variation, we aimed to assess the frequency of this variation, its impact on EDX interpretation, and the role of neuromuscular ultrasound (NMUS) in improving diagnostic accuracy.

Methods

We describe an index patient with median nerve pseudoconduction block in the forearm caused by anatomical variation, confirmed by ultrasound. We then retrospectively reviewed upper limb NMUS performed by a single EDX medicine specialist at University Hospitals Cleveland Medical Center. At the antecubital fossa, the distance between the midpoint of the brachial artery and the midpoint of the median nerve was measured. Available EDX values were reviewed for ultrasounds with marked nerve‐artery separation.

Results

Sixty‐eight patients were included. In all patients, the median nerve lay medial to the brachial artery (range: 2.5–26 mm). Seven patients (10.3%) had nerve‐artery separation greater than 12.5 mm. Of these, five had available EDX data for retrospective review and three (60%) reported either complete or partial CB.

Discussion

True CB suggests significant pathology. NMUS can help distinguish pseudoconduction block from true CB and prevent misdiagnosis. When pseudoconduction block of the median nerve in the forearm is suspected, stimulation 15–25 mm medial to the brachial artery pulse, or slightly more medial and proximal (between the bicep tendon and brachialis muscle) may improve accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Median NerveHumansFemaleUltrasonographyMaleRetrospective StudiesMiddle AgedNeural ConductionNerve Conduction StudiesAgedAdultAged, 80 and over

Stichwörter der Autor:innen

EDXanatomical variantmedian nerve pseudoconduction blockneuromuscular ultrasoundultrasound guided electrodiagnostic testing

Autor:innen und Institutionen

  • Neuromuscular Center & EMG Laboratory, the Neurological Institute, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA.
  • Department of Neurology, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio, USA.

ORCID-Profile: Yajing Ye, Bashar Katirji, Robert D Adams

Zitieren

APA

Ye, Y., Katirji, B., & Adams, R. D. (2026). Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation. Muscle & Nerve. https://doi.org/10.1002/mus.70285

Vancouver

Ye Y, Katirji B, Adams RD. Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation. Muscle & Nerve. 2026. doi:10.1002/mus.70285

BibTeX
@article{Ye2026,
  author = {Ye, Yajing and Katirji, Bashar and Adams, Robert D},
  title = {Ultrasound‐Confirmed Median Nerve Pseudoconduction Block due to Anatomical Variation},
  journal = {Muscle & Nerve},
  year = {2026},
  doi = {10.1002/mus.70285}
}
Kostenlos starten →