EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Differences in corneal nerve fiber density and fiber length in patients with painful chronic idiopathic axonal polyneuropathy and diabetic polyneuropathy

Mariska D Nieuwenhoff iD, Hoang-Ton Nguyen, Sjoerd P Niehof, Frank J P M Huygen, Ajay Verma, Erica S Klaassen, Malik Bechakra, Wouter J Geelhoed, Joost L M Jongen, Annette C Moll, Alexander F J E Vrancken, Axel Petzold iD und 1 weitere

Muscle & Nerve · 2024

DOI: 10.1002/mus.28213 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Muscle & Nerve, 2024. Verfasst von Mariska D Nieuwenhoff und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Medicine, Erasmus MC University Medical Center, Rotterdam, The Netherlands. Hauptthemen laut MEDLINE: Cornea, Nerve Fibers, Diabetic Neuropathies, Microscopy, Confocal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dutch Technology Foundation STW, Biogen, Stichting voor de Technische Wetenschappen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Aims Corneal confocal microscopy (CCM) detects small nerve fiber loss and correlates with skin biopsy findings in diabetic neuropathy. In chronic idiopathic axonal polyneuropathy (CIAP) this correlation is unknown. Therefore, we compared CCM and skin biopsy in patients with CIAP to healthy controls, patients with painful diabetic neuropathy (PDN) and diabetics without overt neuropathy (DM).

Methods

Participants with CIAP and suspected small fiber neuropathy ( n = 15), PDN ( n = 16), DM ( n = 15), and healthy controls ( n = 16) underwent skin biopsy and CCM testing. Inter‐center intraclass correlation coefficients (ICC) were calculated for CCM parameters.

Results

Compared with healthy controls, patients with CIAP and PDN had significantly fewer nerve fibers in the skin (IENFD: 5.7 ± 2.3, 3.0 ± 1.8, 3.9 ± 1.5 fibers/mm, all p < .05). Corneal nerve parameters in CIAP (fiber density 23.8 ± 4.9 no./mm 2 , branch density 16.0 ± 8.8 no./mm 2 , fiber length 13.1 ± 2.6 mm/mm 2 ) were not different from healthy controls (24.0 ± 6.8 no./mm 2 , 22.1 ± 9.7 no./mm 2 , 13.5 ± 3.5 mm/mm 2 , all p > .05). In patients with PDN, corneal nerve fiber density (17.8 ± 5.7 no./mm 2 ) and fiber length (10.5 ± 2.7 mm/mm 2 ) were reduced compared with healthy controls ( p < .05). CCM results did not correlate with IENFD in CIAP patients. Inter‐center ICC was 0.77 for fiber density and 0.87 for fiber length.

Discussion

In contrast to patients with PDN, corneal nerve parameters were not decreased in patients with CIAP and small nerve fiber damage. Therefore, CCM is not a good biomarker for small nerve fiber loss in CIAP patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CorneaNerve FibersDiabetic NeuropathiesMicroscopy, ConfocalHumansMaleFemaleMiddle AgedAgedAdultSkinPolyneuropathies

Stichwörter der Autor:innen

chronic idiopathic axonal polyneuropathycorneal confocal microscopydiabetic neuropathyintra epidermal nerve fiber densitypain

Autor:innen und Institutionen

  • Department of Anesthesiology and Pain Medicine, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
  • Centre for Human Drug Research, Leiden, The Netherlands.
  • Department of Ophthalmology, Amsterdam UMC location VU University Medical Center, Amsterdam, The Netherlands.
  • Biogen, Cambridge, Massachusetts, USA.
  • Department of Neurology, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
  • Department of Neurology, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands.

ORCID-Profile: Mariska D Nieuwenhoff, Axel Petzold

Förderung

  • Dutch Technology Foundation STW
  • Biogen
  • Stichting voor de Technische Wetenschappen

Zitieren

APA

Nieuwenhoff, M. D., Nguyen, H. T., Niehof, S. P., Huygen, F. J. P. M., Verma, A., Klaassen, E. S., Bechakra, M., Geelhoed, W. J., Jongen, J. L. M., Moll, A. C., Vrancken, A. F. J. E., Petzold, A., & Groeneveld, G. J. (2024). Differences in corneal nerve fiber density and fiber length in patients with painful chronic idiopathic axonal polyneuropathy and diabetic polyneuropathy. Muscle & Nerve. https://doi.org/10.1002/mus.28213

Vancouver

Nieuwenhoff MD, Nguyen HT, Niehof SP, Huygen FJPM, Verma A, Klaassen ES, et al. Differences in corneal nerve fiber density and fiber length in patients with painful chronic idiopathic axonal polyneuropathy and diabetic polyneuropathy. Muscle & Nerve. 2024. doi:10.1002/mus.28213

BibTeX
@article{Nieuwenhoff2024,
  author = {Nieuwenhoff, Mariska D and Nguyen, Hoang-Ton and Niehof, Sjoerd P and Huygen, Frank J P M and Verma, Ajay and Klaassen, Erica S and Bechakra, Malik and Geelhoed, Wouter J and Jongen, Joost L M and Moll, Annette C and Vrancken, Alexander F J E and Petzold, Axel and Groeneveld, Geert Jan},
  title = {Differences in corneal nerve fiber density and fiber length in patients with painful chronic idiopathic axonal polyneuropathy and diabetic polyneuropathy},
  journal = {Muscle & Nerve},
  year = {2024},
  doi = {10.1002/mus.28213}
}
Kostenlos starten →