Fachartikel in der Zeitschrift Muscle & Nerve, 2024. Verfasst von Andrea J Boon und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Diaphragm, Ultrasonography, Noninvasive Ventilation. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Aims Point‐of‐care ultrasound of the diaphragm is highly sensitive and specific in the detection of neuromuscular diaphragmatic dysfunction. In some patients with neuromuscular diaphragmatic dysfunction, paradoxical thinning of the diaphragm during inspiration is observed on ultrasound; however, its frequency, electrodiagnostic associations, and prognostic significance remain uncertain.

Methods

Medical records of patients presenting to two electrodiagnostic laboratories (Mayo Clinic, Rochester, Minnesota and University of Alberta, Edmonton, Alberta) from January 1, 2022 to December 31, 2022, for evaluation of suspected neuromuscular respiratory failure, were reviewed.

Results

214 patients were referred and 19 patients excluded due to incomplete information. Of 195 patients (384 hemidiaphragms), 104 had phrenic neuropathy, 12 had myopathy, and 79 had no evidence of neuromuscular disease affecting the diaphragm. Paradoxical thinning occurred in 31 (27%) patients with neuromuscular diaphragmatic dysfunction and was unilateral in 30, the majority (83%) having normal contralateral ultrasound. Phrenic nerve conduction studies and diaphragm electromyography results did not distinguish patients with paradoxical thinning versus without. Most patients (71%) with paradoxical thinning required non‐invasive ventilation (NIV), including 16 with unilateral paradoxical thinning. Paradoxical thinning and BMI ≥30 kg/m 2 were risk factors for requiring NIV in multivariable logistic regression analysis, with odds ratios of 2.887 (95% CI:1.166, 7.151) and 2.561 (95% CI: 1.186, 5.532), respectively.

Discussion

Paradoxical thinning of the diaphragm occurs in patients with prominent neuromuscular diaphragmatic dysfunction, most commonly from phrenic neuropathy, and is a significant risk factor for requiring NIV. Unilateral paradoxical thinning is sufficient for needing NIV. BMI ≥30 kg/m 2 additionally increases risk of requiring NIV in patients with neuromuscular diaphragmatic dysfunction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DiaphragmUltrasonographyNoninvasive VentilationHumansMaleFemaleMiddle AgedAgedRisk FactorsAdultNeuromuscular DiseasesRetrospective StudiesPhrenic NerveElectromyographyRespiratory InsufficiencyAged, 80 and over

Stichwörter der Autor:innen

diaphragmneuromuscular respiratory failurenon‐invasive ventilationparadoxical thinningultrasound

Autor:innen und Institutionen

  • Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Neurology, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Neurology, Wake Forest School of Medicine, Winston-Salem, North Carolina, USA.
  • Division of Neurology, Department of Medicine, University of Alberta, Edmonton, Alberta, Canada.

ORCID-Profile: James B Meiling, Christopher J Klein, Grayson Beecher

Zitieren

APA

Boon, A. J., Meiling, J. B., Luetmer, M. T., Klein, C. J., Sorenson, E. J., Harper, C. M., & Beecher, G. (2024). Paradoxical thinning of the diaphragm on ultrasound is a risk factor for requiring non‐invasive ventilation in patients with neuromuscular diaphragmatic dysfunction. Muscle & Nerve. https://doi.org/10.1002/mus.28194

Vancouver

Boon AJ, Meiling JB, Luetmer MT, Klein CJ, Sorenson EJ, Harper CM, et al. Paradoxical thinning of the diaphragm on ultrasound is a risk factor for requiring non‐invasive ventilation in patients with neuromuscular diaphragmatic dysfunction. Muscle & Nerve. 2024. doi:10.1002/mus.28194

BibTeX
@article{Boon2024,
  author = {Boon, Andrea J and Meiling, James B and Luetmer, Marianne T and Klein, Christopher J and Sorenson, Eric J and Harper, C Michel and Beecher, Grayson},
  title = {Paradoxical thinning of the diaphragm on ultrasound is a risk factor for requiring non‐invasive ventilation in patients with neuromuscular diaphragmatic dysfunction},
  journal = {Muscle & Nerve},
  year = {2024},
  doi = {10.1002/mus.28194}
}
Kostenlos starten →