Diagnostic efficiency of conventional ultrasound, shear wave elastography, and superb microvascular imaging in evaluating ulnar neuropathy at the elbow
Muscle & Nerve · 2024
DOI: 10.1002/mus.28171 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muscle & Nerve, 2024. Verfasst von Yao Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Harbin, China. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Ulnar Neuropathies, Elbow, Ultrasonography. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Heilongjiang Provincial Health Commission, Health Commission of Heilongjiang Province.
Abstract (Originalsprache)
Introduction/Aims The current diagnosis of ulnar neuropathy at the elbow (UNE) relies mainly on the clinical presentation and nerve electrodiagnostic (EDX) testing, which can be uncomfortable and yield false negatives. The aim of this study was to investigate the diagnostic value of conventional ultrasound, shear wave elastography (SWE), and superb microvascular imaging (SMI) in diagnosing UNE.
Methods
We enrolled 40 patients (48 elbows) with UNE and 48 healthy volunteers (48 elbows). The patients were categorized as having mild, moderate or severe UNE based on the findings of EDX testing. The cross‐sectional area (CSA) was measured using conventional ultrasound. Ulnar nerve (UN) shear wave velocity (SWV) and SMI were performed in a longitudinal plane.
Results
Based on the EDX findings, UNE severity was graded as mild in 4, moderate in 10, and severe in 34. The patient group showed increased ulnar nerve CSA and stiffness at the site of maximal enlargement (CSA mean at the site of max enlargement [CSA max ] and SWV mean at the site of max enlargement [SWV max ]), ulnar nerve CSA ratio, and stiffness ratio (elbow‐to‐upper arm), compared with the control group ( p < .001). Furthermore, the severe UNE group showed higher ulnar nerve CSA max and SWV max compared with the mild and moderate UNE groups ( p < .001). The cutoff values for diagnosis of UNE were 9.5 mm2 for CSA max , 3.06 m/s for SWV max , 2.00 for CSA ratio, 1.36 for stiffness ratio, and grade 1 for SMI.
Discussion
Our findings suggest that SWE and SMI are valuable diagnostic tools for the diagnosis and assessment of severity of UNE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- In-Patient Ultrasound Department, Second Affiliated Hospital of Harbin Medical University, Harbin, China.
- Ultrasound Department, Heilongjiang Red Cross Sengong General Hospital, Harbin, China.
- Orthopedics Department, Second Affiliated Hospital of Harbin Medical University, Harbin, China.
ORCID-Profile: Yao Zhang
Förderung
- Heilongjiang Provincial Health Commission
- Health Commission of Heilongjiang Province
Zitieren
APA
Zhang, Y., Liu, W. Y., Xue, W. L., Wu, H., Yuan, Y., Ma, X. Y., Wang, H., & Zhou, X. L. (2024). Diagnostic efficiency of conventional ultrasound, shear wave elastography, and superb microvascular imaging in evaluating ulnar neuropathy at the elbow. Muscle & Nerve. https://doi.org/10.1002/mus.28171
Vancouver
Zhang Y, Liu WY, Xue WL, Wu H, Yuan Y, Ma XY, et al. Diagnostic efficiency of conventional ultrasound, shear wave elastography, and superb microvascular imaging in evaluating ulnar neuropathy at the elbow. Muscle & Nerve. 2024. doi:10.1002/mus.28171
BibTeX
@article{Zhang2024,
author = {Zhang, Yao and Liu, Wei-Yao and Xue, Wei-Li and Wu, Han and Yuan, Yan and Ma, Xin-Yuan and Wang, Hong and Zhou, Xian-Li},
title = {Diagnostic efficiency of conventional ultrasound, shear wave elastography, and superb microvascular imaging in evaluating ulnar neuropathy at the elbow},
journal = {Muscle & Nerve},
year = {2024},
doi = {10.1002/mus.28171}
}
EUVIMED