EUVIMEDEUVIMED entdecken
Crossref

Analysis of the thenar muscles with ultrasound shear wave elastography: Reliability and preliminary findings

Naoya Iida, Tomoyuki Kuroiwa iD, Peter Amadio iD

Muscle & Nerve · 2024

DOI: 10.1002/mus.28004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Muscle & Nerve, 2024. Verfasst von Naoya Iida und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Carpal Tunnel Syndrome. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Aims Ultrasound shear wave elastography (SWE) of the thenar muscles has the potential to provide a simple and noninvasive assessment of the severity of carpal tunnel syndrome (CTS), but its reliability is unknown. The purpose of this study was to assess the intra‐ and inter‐rater reliability of SWE measurements of the elastic modulus of individual thenar muscles, to assess their suitability for clinical application.

Methods

Fourteen healthy volunteers, seven male and seven female, participated in this study. The elastic modulus of the thenar muscles was measured with SWE, with two independent examiners to assess inter‐rater reliability. The first examiner also performed a second measurement after an interval of least 1 day to assess intra‐rater reliability. Reliability was evaluated using an intraclass correlation coefficient (ICC) and 95% confidence interval (CI).

Results

For the abductor pollicis brevis (APB) and opponens pollicis (OPP), the CI of ICC in intra‐rater reliability was 0.47–0.85 and 0.56–0.88, respectively. The CI of ICC in inter‐rater reliability was 0.27–0.78 for the APB and 0.22–0.76 for the OPP. The ICCs of intra‐ and/or inter‐rater reliability of other thenar muscles were less than 0.5.

Discussion

In this study, SWE evaluations of thenar muscles were quite variable in terms of their reliability. A larger study will be needed to determine the source of this variability, improve reliability, and assess the value of SWE in the evaluation of the severity of CTS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesCarpal Tunnel SyndromeHumansMaleFemaleReproducibility of ResultsUltrasonographyMuscle, SkeletalHand

Stichwörter der Autor:innen

elastic modulushandreliabilityshear wave elastographythenar muscle

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA.

ORCID-Profile: Tomoyuki Kuroiwa, Peter Amadio

Zitieren

APA

Iida, N., Kuroiwa, T., & Amadio, P. (2024). Analysis of the thenar muscles with ultrasound shear wave elastography: Reliability and preliminary findings. Muscle & Nerve. https://doi.org/10.1002/mus.28004

Vancouver

Iida N, Kuroiwa T, Amadio P. Analysis of the thenar muscles with ultrasound shear wave elastography: Reliability and preliminary findings. Muscle & Nerve. 2024. doi:10.1002/mus.28004

BibTeX
@article{Iida2024,
  author = {Iida, Naoya and Kuroiwa, Tomoyuki and Amadio, Peter},
  title = {Analysis of the thenar muscles with ultrasound shear wave elastography: Reliability and preliminary findings},
  journal = {Muscle & Nerve},
  year = {2024},
  doi = {10.1002/mus.28004}
}