Optimal needle electromyography approach to the serratus anterior muscle
Muscle & Nerve · 2023
DOI: 10.1002/mus.27933 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muscle & Nerve, 2023. Verfasst von Hee Young Lim und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea. Hauptthemen laut MEDLINE: Muscle, Skeletal, Superficial Back Muscles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben.
Abstract (Originalsprache)
Introduction/Aims There are two conventional needle electromyography (EMG) approaches to the serratus anterior (SA), both of which can result in erroneous insertion into adjacent structures such as the latissimus dorsi (LD), teres major, or external oblique abdominis muscles and pose a risk of long thoracic nerve (LTN) injury. Therefore, we identified a novel needle insertion point for the SA in cadavers that avoids other muscles and LTN injury.
Methods
This study included 17 cadavers: 12 to devise the new method and 5 to verify its accuracy. Novel landmarks were the inferior angle of the scapula ( I ), sternal notch ( S ), and xiphoid process ( X ). The relationships of the LD, pectoralis major (PM), SA, and LTN were determined relative to these landmarks.
Results
When inserting a needle into the proximal one third along the line connecting points I and X , there were adequate safety margins around the LD, PM, and LTN, and the new method had excellent accuracy.
Discussion
Compared to the conventional midaxillary method, our novel method improved the accuracy of needle EMG of the SA. Follow‐up studies using clinical imaging techniques are needed to verify whether above findings are equally applicable in living subjects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rehabilitation Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
- Catholic Institute for Applied Anatomy, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
- Department of Rehabilitation Medicine, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
- Department of Anatomy, College of Korean Medicine, Dongshin University, Jeollanamdo, Korea.
ORCID-Profile: Hee Young Lim, Jong In Lee
Zitieren
APA
Lim, H. Y., Kim, S. H., Choi, J. W., Chang, S. Y., Kim, G. H., Kim, I. B., Nam, Y. S., & Lee, J. I. (2023). Optimal needle electromyography approach to the serratus anterior muscle. Muscle & Nerve. https://doi.org/10.1002/mus.27933
Vancouver
Lim HY, Kim SH, Choi JW, Chang SY, Kim GH, Kim IB, et al. Optimal needle electromyography approach to the serratus anterior muscle. Muscle & Nerve. 2023. doi:10.1002/mus.27933
BibTeX
@article{Lim2023,
author = {Lim, Hee Young and Kim, Sang-Hyun and Choi, Jung-Woo and Chang, So-Youn and Kim, Ga Hye and Kim, In-Beom and Nam, Yong-Seok and Lee, Jong In},
title = {Optimal needle electromyography approach to the serratus anterior muscle},
journal = {Muscle & Nerve},
year = {2023},
doi = {10.1002/mus.27933}
}