Fachartikel in der Zeitschrift Musculoskeletal Care, online erschienen am 23.04.2026. Verfasst von Christopher Alexander Rasmussen und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Danish Centre for Expertise in Rheumatology, Danish Hospital for Rheumatic Diseases, University Hospital of Southern Denmark, Sønderborg, Denmark. Hauptthemen laut MEDLINE: Axial Spondyloarthritis, Spondylitis, Ankylosing, Severity of Illness Index. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
In recent years, the Ankylosing Spondylitis Performance Index (ASPI) has emerged as a new objective measure of physical function in patients with axial spondyloarthritis (axSpA). So far, only the relative interrater reliability of the ASPI test has been reported, but the absolute interrater reliability remains to be investigated.
Objective
This study investigated the interrater absolute and relative reliability of the ASPI test in patients with axSpA from a [Nordic] country.
Methods
Patients with axSpA were recruited from [a Danish] rheumatology outpatient clinic between October and November 2023. The participants performed the ASPI twice with two different raters, with a 15‐min pause between tests. Absolute and relative reliability were assessed.
Results
Fifty‐two participants were included. The standard error measurement for the overall ASPI test was 3.4%, and the minimal detectable difference was 9.5%. The participants performed the ASPI test faster with the second rater (mean 38.15 s (standard deviation, SD 12.16 s) compared to the first rater (40.92 s (SD 12.07 s)) with a statistically significant reduction in time of −2.77 s (SD 4.53 s) ( p < 0.001). The intraclass correlation coefficient of the ASPI test was 0.91 (95% CI 0.76–0.96).
Conclusion
The study showed high absolute interrater reliability with low interrater measurement error for single individuals and groups in patients with axSpA. The relative reliability was also high. However, ASPI demonstrated a learning effect at group level. This study offers clinically relevant guidance for interpreting differences in the ASPI scores when tests are repeated by different raters, relevant for real‐world clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Danish Centre for Expertise in Rheumatology, Danish Hospital for Rheumatic Diseases, University Hospital of Southern Denmark, Sønderborg, Denmark.
- Department of Regional Health Research (IRS), University of Southern Denmark, Odense, Denmark.
- Hospital Soenderjylland, University Hospital of Southern Denmark, Aabenraa, Denmark.
ORCID-Profile: Jette Primdahl, Kirsten Lykke Knak
Zitieren
APA
Rasmussen, C. A., Mink, S. B., Primdahl, J., & Knak, K. L. (2026). Interrater Reliability of the Ankylosing Spondylitis Performance Index in Patients With Axial Spondyloarthritis. Musculoskeletal Care, 24(2). https://doi.org/10.1002/msc.70224
Vancouver
Rasmussen CA, Mink SB, Primdahl J, Knak KL. Interrater Reliability of the Ankylosing Spondylitis Performance Index in Patients With Axial Spondyloarthritis. Musculoskeletal Care. 2026;24(2). doi:10.1002/msc.70224
BibTeX
@article{Rasmussen2026,
author = {Rasmussen, Christopher Alexander and Mink, Sebastian Bülow and Primdahl, Jette and Knak, Kirsten Lykke},
title = {Interrater Reliability of the Ankylosing Spondylitis Performance Index in Patients With Axial Spondyloarthritis},
journal = {Musculoskeletal Care},
year = {2026},
volume = {24},
number = {2},
doi = {10.1002/msc.70224}
}
EUVIMED