EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Interrater Reliability of the Ankylosing Spondylitis Performance Index in Patients With Axial Spondyloarthritis

Christopher Alexander Rasmussen, Sebastian Bülow Mink, Jette Primdahl iD, Kirsten Lykke Knak iD

Musculoskeletal Care · 2026-06 · 24 (2)

DOI: 10.1002/msc.70224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Musculoskeletal Care, online erschienen am 23.04.2026. Verfasst von Christopher Alexander Rasmussen und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Danish Centre for Expertise in Rheumatology, Danish Hospital for Rheumatic Diseases, University Hospital of Southern Denmark, Sønderborg, Denmark. Hauptthemen laut MEDLINE: Axial Spondyloarthritis, Spondylitis, Ankylosing, Severity of Illness Index. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

In recent years, the Ankylosing Spondylitis Performance Index (ASPI) has emerged as a new objective measure of physical function in patients with axial spondyloarthritis (axSpA). So far, only the relative interrater reliability of the ASPI test has been reported, but the absolute interrater reliability remains to be investigated.

Objective

This study investigated the interrater absolute and relative reliability of the ASPI test in patients with axSpA from a [Nordic] country.

Methods

Patients with axSpA were recruited from [a Danish] rheumatology outpatient clinic between October and November 2023. The participants performed the ASPI twice with two different raters, with a 15‐min pause between tests. Absolute and relative reliability were assessed.

Results

Fifty‐two participants were included. The standard error measurement for the overall ASPI test was 3.4%, and the minimal detectable difference was 9.5%. The participants performed the ASPI test faster with the second rater (mean 38.15 s (standard deviation, SD 12.16 s) compared to the first rater (40.92 s (SD 12.07 s)) with a statistically significant reduction in time of −2.77 s (SD 4.53 s) ( p < 0.001). The intraclass correlation coefficient of the ASPI test was 0.91 (95% CI 0.76–0.96).

Conclusion

The study showed high absolute interrater reliability with low interrater measurement error for single individuals and groups in patients with axSpA. The relative reliability was also high. However, ASPI demonstrated a learning effect at group level. This study offers clinically relevant guidance for interpreting differences in the ASPI scores when tests are repeated by different raters, relevant for real‐world clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Axial SpondyloarthritisSpondylitis, AnkylosingSeverity of Illness IndexHumansReproducibility of ResultsFemaleMaleAdultObserver VariationMiddle AgedDenmark

Stichwörter der Autor:innen

ankylosing spondylitisankylosing spondylitis performance indexaxial spondyloarthritisinterrater reliabilityoutcome measures

Autor:innen und Institutionen

  • The Danish Centre for Expertise in Rheumatology, Danish Hospital for Rheumatic Diseases, University Hospital of Southern Denmark, Sønderborg, Denmark.
  • Department of Regional Health Research (IRS), University of Southern Denmark, Odense, Denmark.
  • Hospital Soenderjylland, University Hospital of Southern Denmark, Aabenraa, Denmark.

ORCID-Profile: Jette Primdahl, Kirsten Lykke Knak

Zitieren

APA

Rasmussen, C. A., Mink, S. B., Primdahl, J., & Knak, K. L. (2026). Interrater Reliability of the Ankylosing Spondylitis Performance Index in Patients With Axial Spondyloarthritis. Musculoskeletal Care, 24(2). https://doi.org/10.1002/msc.70224

Vancouver

Rasmussen CA, Mink SB, Primdahl J, Knak KL. Interrater Reliability of the Ankylosing Spondylitis Performance Index in Patients With Axial Spondyloarthritis. Musculoskeletal Care. 2026;24(2). doi:10.1002/msc.70224

BibTeX
@article{Rasmussen2026,
  author = {Rasmussen, Christopher Alexander and Mink, Sebastian Bülow and Primdahl, Jette and Knak, Kirsten Lykke},
  title = {Interrater Reliability of the Ankylosing Spondylitis Performance Index in Patients With Axial Spondyloarthritis},
  journal = {Musculoskeletal Care},
  year = {2026},
  volume = {24},
  number = {2},
  doi = {10.1002/msc.70224}
}
Kostenlos starten →