Combined Metasurface and Metamaterial Passive Transmit Lens and Receive Array for 3 T
Magnetic Resonance in Medicine · 05.11.2026
DOI: 10.1002/mrm.70645 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 05.11.2026. Verfasst von Adam M Maunder und 4 weiteren Autor:innen. Beteiligte Einrichtung: Physics Department, University of Alberta, Edmonton, Alberta, Canada. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Alberta Innovates, Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Purpose
Metasurfaces (MSs) and metamaterials (MMs) can reduce transmit field nulls caused by wavelength effects at higher MR field strengths. We present a layered MM and MS resonant structure that improves transmit field performance when used as a combined slab (i.e., the metaslab ), while also operating as a receive array.
Methods
The MS structure consists of cross‐shaped traces joined by capacitors on a PCB. It is embedded between two layers of a MM consisting of inductively coupled longitudinal strips acting as a 2D transmission line. The two structures are intrinsically decoupled and support connection ports to create an 8‐element receive array. Simulations were performed with a realistic body phantom, and imaging experiments were performed at 3 T on a large water phantom and in vivo on an adult male's abdomen.
Results
Transmit efficiency is improved by a factor of 1.45 in simulation over body coil alone using a realistic body model and by a factor of 1.55 from in vivo measurement. Inhomogeneity is reduced from 24.1% to 17.5% in simulation with realistic human body models, and from 18.5% to 13.9% in phantom measurements. Furthermore, the SAR efficiency is improved by 26% in simulation. In receive, the measured SNR is improved by a factor of 1.48 at the center, compared to a 1.76 improvement with equivalent channel count conventional surface coil array.
Conclusion
The proposed combination of MS and MM operating dually as a passive field lens and receive array improves homogeneity, SAR efficiency, and receive sensitivity for 3 T abdominal MRI.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Physics Department, University of Alberta, Edmonton, Alberta, Canada.
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, Canada.
- Department of Oncology, University of Alberta, Edmonton, Alberta, Canada.
- Cross Cancer Institute, Edmonton, Alberta, Canada.
ORCID-Profile: Adam M Maunder, Léo J E Rémillard, Nicola De Zanche
Förderung
- Alberta Innovates
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Maunder, A. M., Smart, L. P., Rémillard, L. J. E., Iyer, A. K., & De Zanche, N. (2026). Combined Metasurface and Metamaterial Passive Transmit Lens and Receive Array for 3 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70645
Vancouver
Maunder AM, Smart LP, Rémillard LJE, Iyer AK, De Zanche N. Combined Metasurface and Metamaterial Passive Transmit Lens and Receive Array for 3 T. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70645
BibTeX
@article{Maunder2026,
author = {Maunder, Adam M and Smart, Lauren P and Rémillard, Léo J E and Iyer, Ashwin K and De Zanche, Nicola},
title = {Combined Metasurface and Metamaterial Passive Transmit Lens and Receive Array for 3 T},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70645}
}
EUVIMED