Simplified Anisotropic IVIM Using Spherical Means and an Application in the Placenta
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 378-393
DOI: 10.1002/mrm.70598 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 20.09.2026. Verfasst von Paddy J Slator und 8 weiteren Autor:innen. Beteiligte Einrichtung: Cardiff University Brain Research Imaging Centre, School of Psychology, Cardiff, UK. Hauptthemen laut MEDLINE: Placenta, Image Interpretation, Computer-Assisted, Diffusion Magnetic Resonance Imaging. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Leap In Utero Program, Engineering and Physical Sciences Research Council (EPSRC), Wellbeing of Women.
Abstract (Originalsprache)
Purpose
To reduce the complexity associated with anisotropic IVIM modeling, we derived two simplified diffusion MRI models that map the apparent diffusivity, relative proportions, and anisotropy of perfusion‐ and diffusion‐related signal components and demonstrated them in placenta scans.
Methods
We introduce two spherical mean anisotropic intravoxel incoherent motion (IVIM) models. The models consist of constrained diffusion tensor compartments, namely “sticks” or “zeppelins,” and we consider the spherical mean of the signal for these compartments. We apply these spherical mean anisotropic IVIM models to placenta MRI scans from 14 control participants to produce perfusion fraction, perfusion‐related pseudo‐diffusivity, diffusion‐related diffusivity, perfusion‐related fractional anisotropy, and diffusion‐related fractional anisotropy maps. We compare our approach to the standard IVIM model and calculate the Bayesian information criterion voxelwise to determine which model best explains the data.
Results
Spherical mean anisotropic IVIM output maps are consistent with standard IVIM, while additionally accounting for and mapping anisotropy of perfusion‐ and diffusion‐related signal components. Spherical mean anisotropic IVIM models provide a better explanation of the data, as indicated by a lower Bayesian information criterion compared to standard IVIM in 10%–20% of voxels, while retaining sensitivity to the same underlying tissue and perfusion characteristics in the remaining voxels.
Conclusion
Our spherical mean anisotropic IVIM approach can disentangle perfusion‐ and diffusion‐related anisotropy without explicitly estimating directionality. Our approach simplifies the calculation of biomarkers reflecting microcirculatory and microstructural changes in anisotropic tissue by employing models of reduced complexity compared to previous methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Cardiff University Brain Research Imaging Centre, School of Psychology, Cardiff, UK.
- School of Computer Science and Informatics, Cardiff University, Cardiff, UK.
- BHF Manchester Centre for Heart and Lung Magnetic Resonance Research, University of Manchester NHS Foundation Trust, Manchester, UK.
- Division of Cardiovascular Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK.
- Maternal and Fetal Health Research Centre, Institute of Human Development, University of Manchester, Manchester, UK.
- St. Mary's Hospital, Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK.
ORCID-Profile: Paddy J Slator, Alexandra Crawford
Förderung
- Wellcome Leap In Utero Program
- Engineering and Physical Sciences Research Council (EPSRC)
- Wellbeing of Women
- Academy of Medical Sciences
Zitieren
APA
Slator, P. J., Pleva, L., Crawford, A., Higgins, L., Johnstone, E., Heazell, A. E. P., Alexander, D. C., Naish, J. H., & Duhig, K. (2027). Simplified Anisotropic IVIM Using Spherical Means and an Application in the Placenta. Magnetic Resonance in Medicine, 97(1), 378-393. https://doi.org/10.1002/mrm.70598
Vancouver
Slator PJ, Pleva L, Crawford A, Higgins L, Johnstone E, Heazell AEP, et al. Simplified Anisotropic IVIM Using Spherical Means and an Application in the Placenta. Magnetic Resonance in Medicine. 2027;97(1):378-393. doi:10.1002/mrm.70598
BibTeX
@article{Slator2027,
author = {Slator, Paddy J and Pleva, Luke and Crawford, Alexandra and Higgins, Lucy and Johnstone, Edward and Heazell, Alexander E P and Alexander, Daniel C and Naish, Josephine H and Duhig, Kate},
title = {Simplified Anisotropic IVIM Using Spherical Means and an Application in the Placenta},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {378--393},
doi = {10.1002/mrm.70598}
}
EUVIMED