Optimizing Oscillating Diffusion Gradients to Reduce Mechanical Vibration and Acoustic Noise on Ultra‐High Gradient Scanners
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 425-440
DOI: 10.1002/mrm.70580 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 25.08.2026. Verfasst von Xingzhou Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Brain, Noise. Die Arbeit nennt 59 Literaturangaben. Gefördert von: Key Research Development Project of Zhejiang Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Purpose
The deployment of oscillating gradient spin echo (OGSE) diffusion encoding sequences on ultra‐high gradient scanners enables advanced microstructure imaging but induces intense acoustic noise and mechanical vibrations, causing subject discomfort and compromising imaging stability and quantitative accuracy. This study implements Acoustic noise and Vibration Optimized dIffusion gradient Design (AVOID) to mitigate these side effects, facilitating the high‐performance OGSE applications in demanding hardware environments.
Methods
System transfer functions were measured on a 3.0T ultra‐high gradient NeuroFrontier MRI system to characterize hardware responses. The optimization algorithm reshaped OGSE waveforms by redistributing spectral energy away from resonant frequencies while maintaining multiple constraints including hardware limits and desired diffusion encoding spectrum. The optimization was validated by comparing non‐optimized and optimized waveforms through physical measurements, phantom scans, and in vivo human brain scans.
Results
Reductions of up to 10 dBA in predicted sound pressure level and 3.4 dB in vibration power spectral intensity were achieved. In phantom experiments, vibration‐induced artifacts were significantly mitigated, resulting in superior repeatability and lower coefficients of variation in ADC maps, approaching the minimum‐vibration reference by pulsed gradient sequences. In vivo validation demonstrated enhanced acquisition stability and consistent frequency‐dependent ADC trends from 0 to 120 Hz.
Conclusion
The AVOID framework effectively suppressed intense acoustic noise and mechanical vibration induced by strong oscillating gradients on ultra‐high gradient scanners, ensuring a stable and comfortable environment for advanced microstructural imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
- Department of Electrical and Electronic Engineering, Faculty of Science and Engineering, University of Nottingham Ningbo China, Ningbo, Zhejiang, China.
- Central Research Institute, United Imaging Healthcare, Shanghai, China.
- Collaborative Innovation Department, United Imaging Healthcare, Shanghai, China.
- Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Zhejiang University, Hangzhou, Zhejiang, China.
ORCID-Profile: Xingzhou Chen, Liyi Kang, Haotian Li, Chengbo Wang, Dan Wu
Förderung
- Key Research Development Project of Zhejiang Province
- National Natural Science Foundation of China
Zitieren
APA
Chen, X., Kang, L., Li, H., Wang, C., Shuai, Z., Zhu, J., Yuan, J., & Wu, D. (2027). Optimizing Oscillating Diffusion Gradients to Reduce Mechanical Vibration and Acoustic Noise on Ultra‐High Gradient Scanners. Magnetic Resonance in Medicine, 97(1), 425-440. https://doi.org/10.1002/mrm.70580
Vancouver
Chen X, Kang L, Li H, Wang C, Shuai Z, Zhu J, et al. Optimizing Oscillating Diffusion Gradients to Reduce Mechanical Vibration and Acoustic Noise on Ultra‐High Gradient Scanners. Magnetic Resonance in Medicine. 2027;97(1):425-440. doi:10.1002/mrm.70580
BibTeX
@article{Chen2027,
author = {Chen, Xingzhou and Kang, Liyi and Li, Haotian and Wang, Chengbo and Shuai, Zhuming and Zhu, Jiayu and Yuan, Jianmin and Wu, Dan},
title = {Optimizing Oscillating Diffusion Gradients to Reduce Mechanical Vibration and Acoustic Noise on Ultra‐High Gradient Scanners},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {425--440},
doi = {10.1002/mrm.70580}
}
EUVIMED