Repeatability of Metabolic Imaging With Hyperpolarized Pyruvate: Back‐to‐Back Neuroimaging and Blood Analysis
Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 548-556
DOI: 10.1002/mrm.70402 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 23.04.2026. Verfasst von Jun Chen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Advanced Imaging Research Center, the University of Texas Southwestern Medical Center, Dallas, Texas, USA. Hauptthemen laut MEDLINE: Pyruvic Acid, Magnetic Resonance Imaging, Brain, Neuroimaging. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Army Medical Research Acquisition Activity, NCRR NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Purpose
13 C MRI with hyperpolarized [1‐ 13 C]pyruvate enables noninvasive imaging of metabolic pathways. Considering the high dose of pyruvate used in hyperpolarized 13 C‐pyruvate studies, circulating 13 C‐pyruvate and the resulting 13 C‐lactate in plasma may influence subsequent pyruvate metabolism, yet the guidance on consecutive injections does not exist. This study is to characterize blood pyruvate and lactate dynamics following [1‐ 13 C]pyruvate injection and to evaluate the repeatability of 13 C neuroimaging with consecutive pyruvate injections.
Methods
Sixteen healthy adults (mean age, 39.0 ± 15.9 years; 8 men) underwent blood sampling or MRI. Eight participants received bolus injections of non‐hyperpolarized [1‐ 13 C]pyruvate following both overnight fasting and postprandial states. Blood samples were collected at baseline and up to 60 min post‐injection to quantify pyruvate and lactate concentrations and 13 C fractional enrichments using mass spectrometry. In parallel, eight participants underwent 13 C/ 1 H MRI that included two injections of hyperpolarized [1‐ 13 C]pyruvate with intervals of 6–55 min for time‐resolved measurement of 13 C‐pyruvate and 13 C‐lactate in the brain.
Results
Plasma 13 C‐pyruvate peaked within 30 s and returned to baseline within 5–10 min, while 13 C‐lactate peaked at 2–3 min. Lactate 13 C enrichment was higher in fasting versus fed states, and total lactate concentration in blood was unchanged by pyruvate injection. Brain 13 C‐lactate/pyruvate showed excellent repeatability (ICC = 0.9842), with all points within the 95% Bland–Altman limits. Voxel‐wise Pearson's correlation between injections was 0.72 ± 0.22 and within‐subject coefficient of variation was 17.6% ± 4.6%.
Conclusion
Consecutive injections of hyperpolarized [1‐ 13 C]pyruvate yield repeatable blood and brain metabolic measurements in humans, supporting multi‐injection protocols in 13 C MRI studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Advanced Imaging Research Center, the University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Children's Research Institute, the University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Department of Radiology, The University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Howard Hughes Medical Institute, Dallas, Texas, USA.
- McDermott Center for Human Growth and Development, the University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Department of Biomedical Engineering, The University of Texas Southwestern Medical Center, Dallas, Texas, USA.
ORCID-Profile: Sung-Han Lin, Craig R Malloy, Jae Mo Park
Förderung
- U.S. Army Medical Research Acquisition Activity
- NCRR NIH HHS
- NIBIB NIH HHS
- NIDDK NIH HHS
- NIH Office of the Director
- NINDS NIH HHS
- NHLBI NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Chen, J., Lin, S. H., Sudderth, J., Derner, K. A., Harrison, C. E., Zaidi, M., Baxter, J. D., Liticker, J., Erfani, Z., Malloy, C. R., Pinho, M. C., DeBerardinis, R. J., & Park, J. M. (2026). Repeatability of Metabolic Imaging With Hyperpolarized Pyruvate: Back‐to‐Back Neuroimaging and Blood Analysis. Magnetic Resonance in Medicine, 96(2), 548-556. https://doi.org/10.1002/mrm.70402
Vancouver
Chen J, Lin SH, Sudderth J, Derner KA, Harrison CE, Zaidi M, et al. Repeatability of Metabolic Imaging With Hyperpolarized Pyruvate: Back‐to‐Back Neuroimaging and Blood Analysis. Magnetic Resonance in Medicine. 2026;96(2):548-556. doi:10.1002/mrm.70402
BibTeX
@article{Chen2026,
author = {Chen, Jun and Lin, Sung-Han and Sudderth, Jessica and Derner, Kelley A and Harrison, Crystal E and Zaidi, Maheen and Baxter, Jeannie D and Liticker, Jeff and Erfani, Zohreh and Malloy, Craig R and Pinho, Marco C and DeBerardinis, Ralph J and Park, Jae Mo},
title = {Repeatability of Metabolic Imaging With Hyperpolarized Pyruvate: Back‐to‐Back Neuroimaging and Blood Analysis},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {2},
pages = {548--556},
doi = {10.1002/mrm.70402}
}
EUVIMED