EUVIMEDEUVIMED entdecken
Open Access

Adiabatic Pulse Shape Influence on the Orientation Dependence of T 1 ρ Relaxation

Hector L de Moura iD, Mahesh B Keerthivasan iD, Jonathan Samuels iD, Marcelo V W Zibetti iD, Ravinder R Regatte iD

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 611-622

DOI: 10.1002/mrm.70359 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 25.03.2026. Verfasst von Hector L de Moura und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Osteoarthritis, Knee, Image Processing, Computer-Assisted, Knee Joint. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAMS NIH HHS, NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To determine how adiabatic pulse shape influences the balance between magic angle effect (MAE) suppression and T 1 contamination in adiabatic T 1 ρ (Ad T 1 ρ ) mapping of ordered tissues. We systematically compared continuous‐wave (CW), hyperbolic‐secant 4 (HS4), and tan–tanh (TAN) preparations ex vivo, and evaluated the feasibility and repeatability of UTE‐Ad T 1 ρ mapping of the knee in vivo.

Methods

UTE‐Ad T 1 ρ imaging was performed at 3 T. A bovine tendon was imaged at 0°, 55°, and 90° using CW, HS4 (3/6 ms), and TAN (3/6 ms) preparations at spin‐lock amplitudes of 500–1000 Hz. Five healthy volunteers and five patients with knee osteoarthritis were scanned. Data were fit with mono‐exponential (ME) and stretched‐exponential (SE) models. Intrasubject repeatability was assessed in healthy volunteers.

Results

All preparations exhibited strong MAE (anisotropy ratios > 40%). TAN pulses consistently produced lower T 1 ρ values than HS4, indicating reduced T 1 contamination (ex vivo). ME‐ T 1 ρ remained orientation‐dependent across all pulses, whereas the SE parameter α was largely orientation‐independent (anisotropy ratio ≈2%–20%). TAN‐6 ms yielded T 1 ρ values most consistent with CW, while HS4‐6 ms produced substantially higher values in the knee joint. TAN‐6 ms (CV = 3.47%) and HS4‐6 ms (CV = 4.24%) demonstrated better repeatability than CW (CV = 7.24%).

Conclusion

Adiabatic pulse shape strongly influences T 1 contamination, but none of the tested preparations eliminated MAE. TAN‐6 ms offered the best balance of reduced T 1 contamination and high repeatability. The near orientation‐independence of the SE parameter α suggests that it may serve as a more robust biomarker for highly ordered tissues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingOsteoarthritis, KneeImage Processing, Computer-AssistedKnee JointHumansMaleReproducibility of ResultsFemaleCattleAnimalsAdultAlgorithmsTendonsMiddle AgedAnisotropyHealthy VolunteersImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

adiabatic T1ρmagic angle effectquantitative MRIultrashort Echo‐time

Autor:innen und Institutionen

  • Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • Siemens Medical Solutions USA Inc, Malvern, Pennsylvania, USA.
  • Department of Medicine, New York University Grossman School of Medicine, New York, New York, USA.

ORCID-Profile: Hector L de Moura, Mahesh B Keerthivasan, Jonathan Samuels, Marcelo V W Zibetti, Ravinder R Regatte

Förderung

  • NIAMS NIH HHS
  • NIH HHS
  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering
  • National Institute of Arthritis and Musculoskeletal and Skin Diseases
  • National Institutes of Health

Zitieren

APA

L de Moura, H., Keerthivasan, M. B., Samuels, J., Zibetti, M. V. W., & Regatte, R. R. (2026). Adiabatic Pulse Shape Influence on the Orientation Dependence of T 1 ρ Relaxation. Magnetic Resonance in Medicine, 96(2), 611-622. https://doi.org/10.1002/mrm.70359

Vancouver

L de Moura H, Keerthivasan MB, Samuels J, Zibetti MVW, Regatte RR. Adiabatic Pulse Shape Influence on the Orientation Dependence of T 1 ρ Relaxation. Magnetic Resonance in Medicine. 2026;96(2):611-622. doi:10.1002/mrm.70359

BibTeX
@article{LdeMoura2026,
  author = {L de Moura, Hector and Keerthivasan, Mahesh B and Samuels, Jonathan and Zibetti, Marcelo V W and Regatte, Ravinder R},
  title = {Adiabatic Pulse Shape Influence on the Orientation Dependence of T 1 ρ Relaxation},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {611--622},
  doi = {10.1002/mrm.70359}
}
Kostenlos starten →