EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Magnetic Properties of Ferritin at Different Levels of Degradation: Implications for MRI ‐Based Iron Quantification in the Brain

Stefan Ropele iD, Sowmya Sunkara iD, Snježana Radulović iD, Saška Lipovšek iD, Michael Stöger-Pollach iD, Christoph Birkl iD, Walter Gössler iD, Christian Enzinger iD, Gerd Leitinger iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.70241 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Stefan Ropele und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Medical University of Graz, Graz, Austria. Hauptthemen laut MEDLINE: Ferritins, Iron, Magnetic Resonance Imaging, Brain. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Science Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Ferritin's iron core exhibits complex magnetic properties, as suggested by magnetometry and Mössbauer spectroscopy, which remain incompletely understood. In particular, the antiferromagnetic inner core could influence the accuracy of iron quantification using MRI and raise concerns about postmortem validation studies involving degraded ferritin cores.

Methods

Fresh postmortem brain samples from six deceased human subjects were analyzed using energy‐filtered transmission electron microscopy (EFTEM) and electron energy loss spectrometry in scanning mode of the TEM (STEM‐EELS) to visualize and quantify the iron cores of ferritin proteins and estimate their iron content. EFTEM findings were compared with results from mass spectrometry and R 2 * mapping at 3T. Analyses focused on three gray matter regions including the frontal cortex, putamen, and globus pallidus.

Results

Autolysis led to a rapid degradation of ferritin molecules, with fewer than one‐third remaining detectable via EFTEM 24 h postmortem. The degradation followed a single‐exponential decay pattern, suggesting that almost the entire non‐heme iron is stored in ferritin. However, R 2 * relaxation rates did not follow this degradation pattern but instead correlated strongly with total iron content as measured by mass spectrometry.

Conclusion

R 2 * mapping‐derived magnetic susceptibility of ferritin appears to be independent of the structural and magnetic organization of its iron core and shows a linear relationship with total iron content. These findings support the interpretation of ferritin as a simple paramagnet at room temperature, without significant antiferromagnetic contributions. Consequently, susceptibility based postmortem studies focusing on iron accumulation are not affected by autolysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FerritinsIronMagnetic Resonance ImagingBrainHumansMaleFemaleMiddle AgedAgedBrain ChemistryMicroscopy, Electron, TransmissionAdultMass SpectrometryAged, 80 and over

Stichwörter der Autor:innen

R2*degradationferritinironpostmortemvalidation

Substanzen

FerritinsIron

Autor:innen und Institutionen

  • Department of Neurology, Medical University of Graz, Graz, Austria.
  • Division of Cell Biology, Histology and Embryology, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria.
  • Faculty of Medicine, University of Maribor, Maribor, Slovenia.
  • Faculty of Chemistry and Chemical Engineering, University of Maribor, Maribor, Slovenia.
  • University Service Centre for TEM, Technical University Vienna, Vienna, Austria.
  • Institute for Solid State Physics, Technical University Vienna, Vienna, Austria.

ORCID-Profile: Stefan Ropele, Sowmya Sunkara, Snježana Radulović, Saška Lipovšek, Michael Stöger-Pollach, Christoph Birkl, Walter Gössler, Christian Enzinger, Gerd Leitinger

Förderung

  • Austrian Science Fund

Zitieren

APA

Ropele, S., Sunkara, S., Radulović, S., Lipovšek, S., Stöger-Pollach, M., Birkl, C., Gössler, W., Enzinger, C., & Leitinger, G. (2025). Magnetic Properties of Ferritin at Different Levels of Degradation: Implications for MRI ‐Based Iron Quantification in the Brain. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70241

Vancouver

Ropele S, Sunkara S, Radulović S, Lipovšek S, Stöger-Pollach M, Birkl C, et al. Magnetic Properties of Ferritin at Different Levels of Degradation: Implications for MRI ‐Based Iron Quantification in the Brain. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.70241

BibTeX
@article{Ropele2025,
  author = {Ropele, Stefan and Sunkara, Sowmya and Radulović, Snježana and Lipovšek, Saška and Stöger-Pollach, Michael and Birkl, Christoph and Gössler, Walter and Enzinger, Christian and Leitinger, Gerd},
  title = {Magnetic Properties of Ferritin at Different Levels of Degradation: Implications for MRI ‐Based Iron Quantification in the Brain},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.70241}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche