Validation of Intravoxel Incoherent Motion MRI Using Perfused Explanted Human Livers
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70184 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Gregory Simchick und 6 weiteren Autor:innen. Beteiligte Einrichtung: Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Liver, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, Wisconsin Alumni Research Foundation, Department of Medical Physics, University of Wisconsin-Madison.
Abstract (Originalsprache)
Purpose
Evaluate the feasibility of using perfused explanted human livers for validating intravoxel incoherent motion (IVIM).
Methods
Eight ( n = 8) explanted livers from deceased donors were obtained. The portal vein and hepatic artery of each explanted liver were connected to a perfusion system. IVIM data were acquired at four total volumetric flow rates (0, 0.6, 0.9, and 1.2 L/min). For each IVIM dataset, diffusion coefficient ( D ), relaxation‐corrected perfusion signal fraction ( F c ), blood velocity SD ( V b ), and/or pseudo‐diffusion coefficient ( D* ) were estimated. Linear mixed‐effects modeling was performed to determine if the effect of applied flow, flow rate, and fibrosis stage on the estimated IVIM parameters was significant ( F ‐tests), while correcting for temporal effect(s). Liver fibrosis stages were obtained from clinical histology.
Results
D was independent of applied flow and total volumetric flow rate ( p ≥ 0.30). F c was approximately zero when no flow was applied and a positive, non‐negligible value that was independent of flow rate with applied flow ( p < 0.001 and ≥ 0.58 for applied flow and flow rate effects, respectively). V b and D* were dependent on applied flow and flow rate ( p ≤ 0.04 with flow rate effect size ≥ 0.69 mm/s per L/min and 25.7 × 10 −3 mm 2 /s per L/min for V b and D* , respectively). Significantly lower ( p ≤ 0.01) F c , V b , and D* estimates were observed for livers with moderate‐to‐advanced fibrosis (stages F2‐4) compared to no‐to‐mild fibrosis (stages F0‐1) (effect sizes = −0.74%, −0.60 mm/s, and −19.8 × 10 −3 mm 2 /s, respectively).
Conclusion
Perfused explanted human livers from deceased donors may serve as biologically accurate systems for validation of quantitative IVIM techniques.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Mechanical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Surgery, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID-Profile: Gregory Simchick, Diego Hernando
Förderung
- NIH HHS
- Wisconsin Alumni Research Foundation
- Department of Medical Physics, University of Wisconsin-Madison
- Department of Radiology, University of Wisconsin-Madison
- GE Healthcare
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Simchick, G., Rice, J., Gober, L. M., Rice, D., Philip, J., Roldan-Alzate, A., & Hernando, D. (2026). Validation of Intravoxel Incoherent Motion MRI Using Perfused Explanted Human Livers. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70184
Vancouver
Simchick G, Rice J, Gober LM, Rice D, Philip J, Roldan-Alzate A, et al. Validation of Intravoxel Incoherent Motion MRI Using Perfused Explanted Human Livers. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70184
BibTeX
@article{Simchick2026,
author = {Simchick, Gregory and Rice, James and Gober, Leah M and Rice, Daniel and Philip, Jennifer and Roldan-Alzate, Alejandro and Hernando, Diego},
title = {Validation of Intravoxel Incoherent Motion MRI Using Perfused Explanted Human Livers},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70184}
}
EUVIMED