Scanner‐based real‐time automated volumetry reporting of the fetus, amniotic fluid, placenta, and umbilical cord for fetal MRI at 0.55T
Magnetic Resonance in Medicine · 2026-02 · 95 (2) · 975-986
DOI: 10.1002/mrm.70097 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 24.09.2025. Verfasst von Sara Neves Silva und 20 weiteren Autor:innen. Beteiligte Einrichtung: Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Hauptthemen laut MEDLINE: Amniotic Fluid, Magnetic Resonance Imaging, Placenta, Umbilical Cord. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, UK Research and Innovation, ERC Starting Grant.
Abstract (Originalsprache)
Purpose
This work aims to enable real‐time automated intra‐uterine volumetric reporting and fetal weight estimation for fetal MRI, deployed directly on the scanner.
Methods
A multi‐region segmentation nnUNet was trained on 146 images of 73 fetal subjects (coronal and axial orientations) for the parcellation of the fetal head, fetal body, placenta, amniotic fluid, and umbilical cord from whole uterus bSSFP stacks. A reporting tool was then developed to integrate the segmentation outputs into an automated report, providing volumetric measurements, fetal weight estimations, and z‐score visualizations. The complete pipeline was subsequently deployed on a 0.55T MRI scanner, enabling real‐time inference and fully automated reporting in the duration of the acquisition.
Results
The segmentation pipeline was quantitatively and retrospectively evaluated on 36 stacks of 18 fetal subjects and demonstrated sufficient performance for all labels, with high scores (0.98) for the fetus, placenta, and amniotic fluid, and 0.91 for the umbilical cord. The prospective evaluation of the scanner deployment step was successfully performed on 50 cases, with the regional volumetric reports available directly on the scanner.
Conclusions
This work demonstrated the feasibility of multi‐regional intra‐uterine segmentation, fetal weight estimation, and automated reporting in real‐time. This study provides a robust baseline solution for the integration of fully automated scanner‐based measurements into fetal MRI reports.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- Biomedical Computing Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- Smart Imaging Lab, Radiological Institute, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany.
- Department of Congenital Heart Disease, Evelina London Children's Hospital, London, UK.
- Elizabeth Garrett Anderson Institute of Women's Health, University College London, London, UK.
- Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
ORCID-Profile: Sara Neves Silva, Alena Uus, Simi Bansal, Jordina Aviles Verdera, Daniel Cromb, Jana Hutter
Förderung
- NIH HHS
- UK Research and Innovation
- ERC Starting Grant
- Engineering and Physical Sciences Research Council
- Deutsche Forschungsgemeinschaft
- Wellcome Trust
- Medical Research Centre
- High-Tech Agenda of the Free State of Bavaria
Zitieren
APA
Neves Silva, S., Uus, A., Waheed, H., Bansal, S., St Clair, K., Norman, W., Aviles Verdera, J., Cromb, D., Woodgate, T., van Poppel, M., Steinweg, J. K., Matthew, J., Pushparajah, K., Lloyd, D., Kyriakopoulou, V., Siassakos, D., David, A., Hajnal, J. V., Story, L., …, & Hutter, J. (2026). Scanner‐based real‐time automated volumetry reporting of the fetus, amniotic fluid, placenta, and umbilical cord for fetal MRI at 0.55T. Magnetic Resonance in Medicine, 95(2), 975-986. https://doi.org/10.1002/mrm.70097
Vancouver
Neves Silva S, Uus A, Waheed H, Bansal S, St Clair K, Norman W, et al. Scanner‐based real‐time automated volumetry reporting of the fetus, amniotic fluid, placenta, and umbilical cord for fetal MRI at 0.55T. Magnetic Resonance in Medicine. 2026;95(2):975-986. doi:10.1002/mrm.70097
BibTeX
@article{NevesSilva2026,
author = {Neves Silva, Sara and Uus, Alena and Waheed, Hadi and Bansal, Simi and St Clair, Kamilah and Norman, Wendy and Aviles Verdera, Jordina and Cromb, Daniel and Woodgate, Tomas and van Poppel, Milou and Steinweg, Johannes K and Matthew, Jacqueline and Pushparajah, Kuberan and Lloyd, David and Kyriakopoulou, Vanessa and Siassakos, Dimitris and David, Anna and Hajnal, Joseph V and Story, Lisa and Rutherford, Mary A and Hutter, Jana},
title = {Scanner‐based real‐time automated volumetry reporting of the fetus, amniotic fluid, placenta, and umbilical cord for fetal MRI at 0.55T},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {95},
number = {2},
pages = {975--986},
doi = {10.1002/mrm.70097}
}