Bidirectional crusher gradient method to estimate the labeling efficiency of pseudo‐continuous arterial spin labeling MRI in mice
Magnetic Resonance in Medicine · 2026-02 · 95 (2) · 912-926
DOI: 10.1002/mrm.70086 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 17.09.2025. Verfasst von Xiuli Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted, Magnetic Resonance Angiography. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIBIB NIH HHS, NIA NIH HHS, NIH HHS.
Abstract (Originalsprache)
Purpose
To develop an experimental method for measuring the labeling efficiency of pseudo‐continuous arterial spin labeling (pCASL) MRI in mice.
Methods
We propose a method using bidirectional crusher gradients to modulate vascular signals in the azygos pericallosal artery (azPA) of the mouse brain, applied with and without pCASL labeling. The combination of corresponding signals allows the estimation of labeling efficiency. A series of studies were conducted to optimize post‐labeling delay, labeling duration, TR, and slice thickness. The sensitivity of labeling efficiency measurements to changes in the labeling scheme was examined. Finally, a physiological challenge with 5% CO 2 was used to assess the potential effect of hypercapnia on labeling efficiency.
Results
Upon systematic testing, optimal acquisition parameters included a labeling duration ≥1170 ms, a TR of 3 s, and an imaging slice thickness of 0.75 mm. To quantitatively estimate labeling efficiency, the bolus arrival time to azPA was required and found to be 209.2 ± 19.1 ms. Typical labeling efficiencies in mouse pCASL scans were 0.780 ± 0.048 (mean ± SD). Furthermore, hypercapnia was found to increase pCASL labeling efficiency.
Conclusion
Our proposed method facilitates perfusion measurement using pCASL MRI by accounting for intersubject variations in labeling efficiency, offering great potential for applications in pathophysiological studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA.
- Children's National Hospital, Washington, District of Columbia, USA.
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
ORCID-Profile: Maria Guadalupe Mora Alvarez, Zhiliang Wei
Förderung
- NIBIB NIH HHS
- NIA NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Yang, X., Li, Y., Bibic, A., Mora Alvarez, M. G., Lu, H., & Wei, Z. (2026). Bidirectional crusher gradient method to estimate the labeling efficiency of pseudo‐continuous arterial spin labeling MRI in mice. Magnetic Resonance in Medicine, 95(2), 912-926. https://doi.org/10.1002/mrm.70086
Vancouver
Yang X, Li Y, Bibic A, Mora Alvarez MG, Lu H, Wei Z. Bidirectional crusher gradient method to estimate the labeling efficiency of pseudo‐continuous arterial spin labeling MRI in mice. Magnetic Resonance in Medicine. 2026;95(2):912-926. doi:10.1002/mrm.70086
BibTeX
@article{Yang2026,
author = {Yang, Xiuli and Li, Yuguo and Bibic, Adnan and Mora Alvarez, Maria Guadalupe and Lu, Hanzhang and Wei, Zhiliang},
title = {Bidirectional crusher gradient method to estimate the labeling efficiency of pseudo‐continuous arterial spin labeling MRI in mice},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {95},
number = {2},
pages = {912--926},
doi = {10.1002/mrm.70086}
}
EUVIMED