Dynamic pseudo‐continuous arterial spin labeling angiography using a 3D ‐radial multi‐spoke spoiled gradient‐recalled sequence
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Andreas Petrovic und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Monash Health, Clayton, Victoria, Australia. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Imaging, Three-Dimensional, Cerebral Angiography. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIHR Oxford Biomedical Research Centre, National Health and Medical Research Council, Wellcome Trust.
Abstract (Originalsprache)
Purpose
Accurate identification of arterial feeders and draining veins is critical for treatment decision‐making in patients with intracranial high‐flow vascular lesions. Currently available MRI sequences lack the temporal and spatial resolution needed for this task. A novel time‐resolved pseudo‐continuous arterial spin labeling (ASL) angiography sequence with high spatial and temporal resolution was developed, and image quality metrics relevant to clinical performance were assessed.
Methods
Ten volunteers and eight patients with intracranial high‐flow vascular lesions underwent a brain MRI protocol, augmented with the new sequence with multi‐spoke (1–3) readouts and dynamic, sliding‐window reconstruction. For each of the acquisitions, image quality was assessed using a 5‐point Likert scale, as well as SNR and SNR efficiency. Spatial and temporal resolution and acquisition time were compared with standard‐of‐care sequences used to assess high‐flow vascular lesions.
Results
The time‐resolved angiographic sequence achieved high isotropic spatial resolution (0.68 mm 3 ), comparable to time of flight (TOF) MRA, but higher than that of contrast‐enhanced (CE)‐MRA, and a higher temporal resolution (200 ms) than CE‐MRA. Multi‐spoke acquisitions demonstrated a significant increase in SNR and SNR efficiency compared to single‐spoke acquisitions while maintaining an overall high image quality rating and at a 31% reduced scan time relative to the single‐spoke variant.
Conclusion
This study demonstrated the clinical feasibility of a novel time‐resolved ASL sequence using a multi‐spoke 3D‐radial readout with a vessel‐signal optimized flip angle sweep. Sufficient SNR, superior spatial and temporal resolution to CE‐MRA, and a comparable spatial resolution to TOF MRA were achieved in a clinically reasonable acquisition time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Monash Health, Clayton, Victoria, Australia.
- Department of Radiology and Radiological Sciences, Monash University, Clayton, Victoria, Australia.
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
- Department of Neurosurgery, Monash Health, Clayton, Victoria, Australia.
ORCID-Profile: Andreas Petrovic, Martin Soellradl, Thomas W Okell
Förderung
- NIHR Oxford Biomedical Research Centre
- National Health and Medical Research Council
- Wellcome Trust
- AOU NIH HHS
- NIBIB NIH HHS
- Wellcome Trust and Royal Society
- Royal Society
- All of Us Research Program
Zitieren
APA
Petrovic, A., Soellradl, M., Okell, T. W., Gauden, A., Lai, L., Amukotuwa, S. A., & Bammer, R. (2026). Dynamic pseudo‐continuous arterial spin labeling angiography using a 3D ‐radial multi‐spoke spoiled gradient‐recalled sequence. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70015
Vancouver
Petrovic A, Soellradl M, Okell TW, Gauden A, Lai L, Amukotuwa SA, et al. Dynamic pseudo‐continuous arterial spin labeling angiography using a 3D ‐radial multi‐spoke spoiled gradient‐recalled sequence. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70015
BibTeX
@article{Petrovic2026,
author = {Petrovic, Andreas and Soellradl, Martin and Okell, Thomas W and Gauden, Andrew and Lai, Leon and Amukotuwa, Shalini A and Bammer, Roland},
title = {Dynamic pseudo‐continuous arterial spin labeling angiography using a 3D ‐radial multi‐spoke spoiled gradient‐recalled sequence},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70015}
}
EUVIMED