Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Seonyeong Shin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany. Hauptthemen laut MEDLINE: Cerebrospinal Fluid, Brain, Magnetic Resonance Imaging. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Marie Skłodowska-Curie Actions.
Abstract (Originalsprache)
Purpose
Although conventional multi‐echo gradient‐echo (GRE) sequences effectively quantify short and intermediate T 2 * in brain tissue, and general interest in cerebrospinal fluid (CSF) is growing due to its association with the glymphatic system, quantifying T 2 * in CSF remains underexplored. Accurate quantification of the slow‐relaxing water pools requires imaging at long echo times, significantly increasing acquisition time. This study proposes a novel sequence capable of quantifying the entire range of T 2 * without prolonged acquisition time, mapping T 2 * in both CSF and brain tissue.
Methods
The proposed echo‐shifted, multi‐echo GRE (ES‐mGRE) combines the conventional multi‐echo GRE sequence with an echo‐shifting technique. Additional gradients are introduced, producing echoes in the next sub–repetition time interval.
Results
ES‐mGRE generates artifact‐free images at both short and long echo times without extending acquisition time. Increasing the area of the additional gradients enhances diffusion sensitivity, allowing simultaneous quantification of T 2 * and D in CSF. The mean T 2 * of white matter and gray matter is 55.9 ms and 51.5 ms at 3 T, respectively. The mean T 2 * in the ventricles is 234.5 ms. The simultaneously quantified mean D value of 3.07 μm 2 /ms is closely aligned with the reference diffusivity.
Conclusion
We demonstrate that the proposed ES‐mGRE sequence can effectively quantify the T 2 * of both CSF and brain tissue while also providing simultaneous diffusion information.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany.
- RWTH Aachen University, Aachen, Germany.
- Institute of Neuroscience and Medicine 11, INM-11, JARA, Forschungszentrum Jülich, Jülich, Germany.
- JARA - BRAIN - Translational Medicine, Aachen, Germany.
- Department of Neurology, RWTH Aachen University, Aachen, Germany.
ORCID-Profile: Seonyeong Shin, Ana-Maria Oros-Peusquens, Seong Dae Yun, N Jon Shah
Förderung
- Deutsche Forschungsgemeinschaft
- Marie Skłodowska-Curie Actions
Zitieren
APA
Shin, S., Oros-Peusquens, A. M., Yun, S. D., Farrher, E., & Shah, N. J. (2025). Development of an echo‐shifted, multi‐echo, gradient‐echo sequence for T 2 * quantification of slow‐relaxing water pools. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30624
Vancouver
Shin S, Oros-Peusquens AM, Yun SD, Farrher E, Shah NJ. Development of an echo‐shifted, multi‐echo, gradient‐echo sequence for T 2 * quantification of slow‐relaxing water pools. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30624
BibTeX
@article{Shin2025,
author = {Shin, Seonyeong and Oros-Peusquens, Ana-Maria and Yun, Seong Dae and Farrher, Ezequiel and Shah, N Jon},
title = {Development of an echo‐shifted, multi‐echo, gradient‐echo sequence for T 2 * quantification of slow‐relaxing water pools},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30624}
}
EUVIMED