EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Automated fibrosis segmentation from wideband post‐contrast T1∗$$ {T}_1^{\ast } $$ mapping in an animal model of ischemic heart disease with implantable cardioverter‐defibrillators

Calder D Sheagren iD, Terenz Escartin, Jaykumar H Patel iD, Jennifer Barry, Graham A Wright

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30468 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Calder D Sheagren und 4 weiteren Autor:innen. Beteiligte Einrichtung: Medical Biophysics, University of Toronto, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Myocardial Ischemia, Defibrillators, Implantable, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: CIHR, Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Post‐contrast mapping has proven promising for automated scar segmentation in subjects without ICDs, but this has not been implemented in patients with ICDs. We introduce an automated cluster‐based thresholding method for maps with an ICD present and compare it to manually tuned thresholding of synthetic LGE images with an ICD present and standard LGE without an ICD present.

Methods

Seven swine received an ischemia‐reperfusion myocardial infarction and were imaged at 3 T 4–5 weeks post‐infarct with and without an ICD. Mapping‐based thresholding was performed using synthetic LGE and artifact‐corrected cluster‐thresholding methods, both employing connected component filtering. Standard pixel signal intensity thresholding was performed on the conventional LGE without an ICD. Volumetric accuracy is relative to conventional LGE and Dice similarity between SynLGE and cluster‐based segmentations were evaluated.

Results

No statistical significance was observed between LGE volumes without an ICD and both SynLGE and artifact‐corrected cluster‐threshold volumes with an ICD, when using connected component filtering. Additionally, Dice alignment between SynLGE and cluster‐thresholding was high for healthy myocardium (0.96), dense scar (0.83), and dense scar union gray zone (0.91) when artifact correction and connected component filtering were implemented.

Conclusion

Clustering of maps holds promise for a reproducible approach to scar segmentation in the presence of ICDs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial IschemiaDefibrillators, ImplantableMagnetic Resonance ImagingImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedAnimalsSwineDisease Models, AnimalFibrosisAlgorithmsReproducibility of ResultsContrast Media

Stichwörter der Autor:innen

gadolinium contrastquantitative fibrosis analysiswideband T1 mapping

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
  • Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.

ORCID-Profile: Calder D Sheagren, Jaykumar H Patel

Förderung

  • CIHR
  • Canadian Institutes of Health Research

Zitieren

APA

Sheagren, C. D., Escartin, T., Patel, J. H., Barry, J., & Wright, G. A. (2025). Automated fibrosis segmentation from wideband post‐contrast T1∗$$ {T}_1^{\ast } $$ mapping in an animal model of ischemic heart disease with implantable cardioverter‐defibrillators. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30468

Vancouver

Sheagren CD, Escartin T, Patel JH, Barry J, Wright GA. Automated fibrosis segmentation from wideband post‐contrast T1∗$$ {T}_1^{\ast } $$ mapping in an animal model of ischemic heart disease with implantable cardioverter‐defibrillators. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30468

BibTeX
@article{Sheagren2025,
  author = {Sheagren, Calder D and Escartin, Terenz and Patel, Jaykumar H and Barry, Jennifer and Wright, Graham A},
  title = {Automated fibrosis segmentation from wideband post‐contrast T1∗$$ T_1^\ast  $$ mapping in an animal model of ischemic heart disease with implantable cardioverter‐defibrillators},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30468}
}
Kostenlos starten →