Composite spin probes with adjustable oxygen sensitivity for pulse electron paramagnetic resonance imaging
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30418 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Irene Canavesi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Oxygen, Spin Labels. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIBIB NIH HHS, National Science Foundation.
Abstract (Originalsprache)
Purpose
Solid crystalline spin probes, such as lithium phthalocyanine (LiPc) and lithium octa‐n‐butoxynaphthalocyanine (LiNc‐BuO), allow repeated oxygen measurement using electron paramagnetic resonance (EPR). Due to their short relaxation times, their use for pulse EPR oxygen imaging is limited. In this study, we developed and tested a new class of solid composite spin probes that modified the relaxation rates R 1 and R 2 of LiPc or LiNc‐BuO probes, which allowed pO 2 measurements in the full dynamic (0–760 torr) range.
Methods
The composite probes were developed by embedding LiPc or LiNc‐BuO with bonewax, beeswax, or petroleum jelly. All experiments were performed using a 25‐mT EPR imager, JIVA‐25®. A selected composite probe, LiPc‐BW5 (LiPc + 5‐times bonewax), was tested for its in vivo stability and robustness using oxygen‐enhanced EPR oxygen imaging. As another application, a LiPc‐BW5‐based marker was tested to outline the SCC7 tumor in a C3H mouse.
Results
The composite probes showed an increased oxygen measurement range compared with unaltered probes. The in vivo experiments with LiPc‐BW5 showed the stability of the probes for repeated oxygen imaging up to 4 weeks of measurements. The in vivo pO 2 at the subcutaneous site changed from 26.1 ± 1.9 torr to 118.9 ± 1.9 torr when the breathing gas was changed from 21% O 2 to 100% O 2 . The use of LiPc‐BW5 as a fiducial marker showed its use in outlining the tumor boundaries.
Conclusions
We developed a new class of robust and versatile solid composite probes with adjustable oxygen sensitivity that allows pO 2 imaging in the broad dynamic range.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.
- Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois, USA.
- Department of Radiology, Geisel School of Medicine at Dartmouth College, Lebanon, New Hampshire, USA.
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID-Profile: Boris Epel, Periannan Kuppusamy, Mark David Pagel, Mrignayani Kotecha
Förderung
- NCI NIH HHS
- NIBIB NIH HHS
- National Science Foundation
- National Institutes of Health
Zitieren
APA
Canavesi, I., Viswakarma, N., Khurana, R., Epel, B., Kuppusamy, P., Pagel, M. D., & Kotecha, M. (2025). Composite spin probes with adjustable oxygen sensitivity for pulse electron paramagnetic resonance imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30418
Vancouver
Canavesi I, Viswakarma N, Khurana R, Epel B, Kuppusamy P, Pagel MD, et al. Composite spin probes with adjustable oxygen sensitivity for pulse electron paramagnetic resonance imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30418
BibTeX
@article{Canavesi2025,
author = {Canavesi, Irene and Viswakarma, Navin and Khurana, Raman and Epel, Boris and Kuppusamy, Periannan and Pagel, Mark David and Kotecha, Mrignayani},
title = {Composite spin probes with adjustable oxygen sensitivity for pulse electron paramagnetic resonance imaging},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30418}
}
EUVIMED