Layer‐specific BOLD effects in gradient and spin‐echo acquisitions in somatosensory cortex
Magnetic Resonance in Medicine · 2025-03 · 93 (3) · 1314-1328
DOI: 10.1002/mrm.30326 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 07.10.2024. Verfasst von Zhangyan Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Hauptthemen laut MEDLINE: Somatosensory Cortex, Saimiri, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 85 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NINDS NIH HHS, NICHD NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Purpose
Previous studies have shown varied BOLD signals with gradient echo (GE) across cortical depth. To interpret these variations, and understand the effects of vascular geometry and size, the magnitudes and layer distributions of GE and spin‐echo (SE) BOLD functional MRI signals were compared in the somatosensory cortex of squirrel monkeys during tactile stimulation and in a resting state at high spatial resolution and high field.
Methods
A block‐design stimulation was used to identify tactile‐evoked activation signals in somatosensory Areas 3b and 1. Layer‐specific connectivities were calculated using resting‐state data. Signal power spectra were compared by depth and pulse sequence. The measured ratios of transverse relaxation rate changes were compared with Anderson and Weiss's model.
Results
SE signals showed a 26% lower percentage signal change during tactile stimulation compared with GE, along with a slower time course. SE signals remained consistent but weaker in lower layers, whereas GE signals decreased with cortical depth. This pattern extended to resting‐state power spectra. Resting‐state functional connectivity indicated larger connectivity between the top layers of Area 3b and Area 1 for GE, with minimal changes for SE. Comparisons with theory suggest vessel diameters ranging from 19.4 to 9 microns are responsible for BOLD effects across cortical layers at 9.4 T.
Conclusion
These results provide further evidence that at high field, SE BOLD signals are relatively free of contributions from sources other than microvascular changes in response to neural activity, whereas GE signals, even in the superficial layers, are not dominated by very large vessels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA.
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
- Department of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee, USA.
ORCID-Profile: Zhangyan Yang, Feng Wang
Förderung
- NINDS NIH HHS
- NICHD NIH HHS
- NIBIB NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Yang, Z., Arabinda, M., Wang, F., Chen, L. M., & Gore, J. C. (2025). Layer‐specific BOLD effects in gradient and spin‐echo acquisitions in somatosensory cortex. Magnetic Resonance in Medicine, 93(3), 1314-1328. https://doi.org/10.1002/mrm.30326
Vancouver
Yang Z, Arabinda M, Wang F, Chen LM, Gore JC. Layer‐specific BOLD effects in gradient and spin‐echo acquisitions in somatosensory cortex. Magnetic Resonance in Medicine. 2025;93(3):1314-1328. doi:10.1002/mrm.30326
BibTeX
@article{Yang2025,
author = {Yang, Zhangyan and Arabinda, Mishra and Wang, Feng and Chen, Li Min and Gore, John C},
title = {Layer‐specific BOLD effects in gradient and spin‐echo acquisitions in somatosensory cortex},
journal = {Magnetic Resonance in Medicine},
year = {2025},
volume = {93},
number = {3},
pages = {1314--1328},
doi = {10.1002/mrm.30326}
}
EUVIMED