Measurement of T 1ρ dispersion with compressed sensing and magnetization prepared radial balanced steady‐state free precession in spontaneous human osteoarthritis
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30206 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von S Pala und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Technical Physics, University of Eastern Finland, Kuopio, Finland. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cartilage, Articular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020 Framework Programme, Research Council of Finland (Flagship of Advanced Mathematics for Sensing, Imaging and Modelling Grant), Sigrid Jusélius Foundation.
Abstract (Originalsprache)
Purpose
To assess the potential for accelerating continuous‐wave (CW) T 1 ρ dispersion measurement with compressed sensing approach via studying the effect that the data reduction has on the ability to detect differences between intact and degenerated articular cartilage with different spin‐lock amplitudes and to assess quantitative bias due to acceleration.
Methods
Osteochondral plugs ( n = 27, 4 mm diameter) from femur ( n = 14) and tibia ( n = 13) regions from human cadaver knee joints were obtained from commercial biobank (Science Care, USA) under Ethical permission 134/2015. MRI of specimens was performed at 9.4T with magnetization prepared radial balanced SSFP (bSSFP) readout sequence, and the CWT 1ρ relaxation time maps were computed from the measured data. The relaxation time maps were evaluated in the cartilage zones for different acceleration factors. For reference, Osteoarthritis Research Society International (OARSI) grading and biomechanical measurements were performed and correlated with the MRI findings.
Results
Four‐fold acceleration of CWT 1ρ dispersion measurement by compressed sensing approach was feasible without meaningful loss in the sensitivity to osteoarthritic (OA) changes within the articular cartilage. Differences were significant between intact and OA groups in the superficial and transitional zones, and CWT 1ρ correlated moderately with the reference measurements (0.3 < r < 0.7).
Conclusion
CWT 1ρ was able to differentiate between intact and OA cartilage even with four‐fold acceleration. This indicates that acceleration of CWT 1ρ dispersion measurement by compressed sensing approach is feasible with negligible loss in the sensitivity to osteoarthritic changes in articular cartilage.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.
ORCID-Profile: S Pala, A Paajanen, O Nykänen, M J Nissi
Förderung
- Horizon 2020 Framework Programme
- Research Council of Finland (Flagship of Advanced Mathematics for Sensing, Imaging and Modelling Grant)
- Sigrid Jusélius Foundation
- Olvi Foundation
- Päivikki and Sakari Sohlberg Foundation
- Instrumentarium Science foundation
- Finnish Cultural Foundation, North-Savonia Regional Fund
- Academy of Finland
Zitieren
APA
Pala, S., Paajanen, A., Ristaniemi, A., Nippolainen, E., Afara, I. O., Nykänen, O., & Nissi, M. J. (2024). Measurement of T 1ρ dispersion with compressed sensing and magnetization prepared radial balanced steady‐state free precession in spontaneous human osteoarthritis. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30206
Vancouver
Pala S, Paajanen A, Ristaniemi A, Nippolainen E, Afara IO, Nykänen O, et al. Measurement of T 1ρ dispersion with compressed sensing and magnetization prepared radial balanced steady‐state free precession in spontaneous human osteoarthritis. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30206
BibTeX
@article{Pala2024,
author = {Pala, S and Paajanen, A and Ristaniemi, A and Nippolainen, E and Afara, I O and Nykänen, O and Nissi, M J},
title = {Measurement of T 1ρ dispersion with compressed sensing and magnetization prepared radial balanced steady‐state free precession in spontaneous human osteoarthritis},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30206}
}
EUVIMED