Characterization of the orientation dependence of magnetization transfer measures in single and crossing‐fiber white matter
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30195 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Philippe Karan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Sherbrooke Connectivity Imaging Laboratory (SCIL), Université de Sherbrooke, Sherbrooke, Canada. Hauptthemen laut MEDLINE: White Matter, Diffusion Tensor Imaging. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Université de Sherbrooke Institutional Chair in Neuroinformatics from Pr Descoteaux, Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Purpose
To fully characterize the orientation dependence of magnetization transfer (MT) and inhomogeneous MT (ihMT) measures in the whole white matter (WM), for both single‐fiber and crossing‐fiber voxels.
Methods
A characterization method was developed using the fiber orientation obtained from diffusion MRI (dMRI) with diffusion tensor imaging (DTI) and constrained spherical deconvolution. This allowed for characterization of the orientation dependence of measures in all of WM, regardless of the number of fiber orientation in a voxel. Furthermore, the orientation dependence inside 31 different WM bundles was characterized to evaluate the homogeneity of the effect. Variation of the results within and between‐subject was assessed from a 12‐subject dataset.
Results
Previous results for single‐fiber voxels were reproduced and a novel characterization was produced in voxels of crossing fibers, which seems to follow trends consistent with single‐fiber results. Heterogeneity of the orientation dependence across bundles was observed, but homogeneity within similar bundles was also highlighted. Differences in behavior between MT and ihMT measures, as well as the ratio and saturation versions of these, were noted.
Conclusion
Orientation dependence characterization was proven possible over the entirety of WM. The vast range of effects and subtleties of the orientation dependence on MT measures showed the need for, but also the challenges of, a correction method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sherbrooke Connectivity Imaging Laboratory (SCIL), Université de Sherbrooke, Sherbrooke, Canada.
- MR Clinical Science, Philips Healthcare Canada, Mississauga, Canada.
- Pharma Research and Early Development, Neuroscience and Rare Diseases Roche Innovation Center Basel, Basel, Switzerland.
ORCID-Profile: Philippe Karan
Förderung
- Université de Sherbrooke Institutional Chair in Neuroinformatics from Pr Descoteaux
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Karan, P., Edde, M., Gilbert, G., Barakovic, M., Magon, S., & Descoteaux, M. (2024). Characterization of the orientation dependence of magnetization transfer measures in single and crossing‐fiber white matter. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30195
Vancouver
Karan P, Edde M, Gilbert G, Barakovic M, Magon S, Descoteaux M. Characterization of the orientation dependence of magnetization transfer measures in single and crossing‐fiber white matter. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30195
BibTeX
@article{Karan2024,
author = {Karan, Philippe and Edde, Manon and Gilbert, Guillaume and Barakovic, Muhamed and Magon, Stefano and Descoteaux, Maxime},
title = {Characterization of the orientation dependence of magnetization transfer measures in single and crossing‐fiber white matter},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30195}
}
EUVIMED