EUVIMEDEUVIMED entdecken
Crossref

Collagen degradation assessment with an in vitro rotator cuff tendinopathy model using multiparametric ultrashort‐TE magnetization transfer (UTE‐MT) imaging

Tan Guo iD, Yan Song, Jinlian Tong, Sheng Jiao, Cheng Shen, Hong Wang, Ju Cui, Dapeng Dai, Jie Ma, Min Chen

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30144 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Tan Guo und 9 weiteren Autor:innen. Beteiligte Einrichtung: Peking University Fifth School of Clinical Medicine, Beijing, China. Hauptthemen laut MEDLINE: Tendinopathy, Collagen, Rotator Cuff, Magnetic Resonance Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National High Level Hospital Clinical Research Funding, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to assess ultrashort‐TE magnetization transfer (UTE‐MT) imaging of collagen degradation using an in vitro model of rotator cuff tendinopathy.

Methods

Thirty‐six supraspinatus tendon specimens were divided into three groups and treated with 600 U collagenase (Group 1), 150 U collagenase (Group 2), and phosphate buffer saline (Group 3). UTE‐MT imaging was performed to assess changes in macromolecular fraction (MMF), macromolecule transverse relaxation time ( T 2m ), water longitudinal relaxation rate constant ( R 1m ), the magnetization exchange rate from the macromolecular to water pool ( Rm 0 w ) and from water to the macromolecular pool ( Rm 0 m ), and magnetization transfer ratio (MTR) at baseline and following digestion and their differences between groups. Biochemical and histological studies were conducted to determine the extent of collagen degradation. Correlation analyses were performed with MMF, T 2 m , R 1 m , Rm 0 w , Rm 0 m , and MTR, respectively. Univariate and multivariate linear regression analyses were performed to evaluate combinations of UTE‐MT parameters to predict collagen degradation.

Results

MMF, T 2 m , R 1 m , Rm 0 m , and MTR decreased after digestion. MMF ( r = −0.842, p < 0.001), MTR ( r = −0.78, p < 0.001), and Rm 0 m ( r = −0.662, p < 0.001) were strongly negatively correlated with collagen degradation. The linear regression model of differences in MMF and Rm 0 m before and after digestion explained 68.9% of collagen degradation variation in the tendon. The model of postdigestion in MMF and T 2m and the model of MTR explained 54.2% and 52.3% of collagen degradation variation, respectively.

Conclusion

This study highlighted the potential of UTE‐MT parameters for evaluation of supraspinatus tendinopathy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TendinopathyCollagenRotator CuffMagnetic Resonance ImagingHumansMaleFemaleMiddle AgedAgedCollagenasesTendonsImage Processing, Computer-Assisted

Stichwörter der Autor:innen

UTEcollagen degradationmagnetization transferrotator cuff tendinopathy

Substanzen

CollagenCollagenases

Autor:innen und Institutionen

  • Peking University Fifth School of Clinical Medicine, Beijing, China.
  • Department of Radiology, Beijing Hospital, National Center of Gerontology; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China.
  • Biotherapy Center, Beijing Hospital, National Center of Gerontology; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China.
  • The Key Laboratory of Geriatrics, Beijing Institute of Geriatrics, Institute of Geriatric Medicine, Chinese Academy of Medical Science, Beijing Hospital/National Center of Gerontology of National Health Commission, Beij…

ORCID-Profile: Tan Guo

Förderung

  • National High Level Hospital Clinical Research Funding
  • National Natural Science Foundation of China

Zitieren

APA

Guo, T., Song, Y., Tong, J., Jiao, S., Shen, C., Wang, H., Cui, J., Dai, D., Ma, J., & Chen, M. (2024). Collagen degradation assessment with an in vitro rotator cuff tendinopathy model using multiparametric ultrashort‐TE magnetization transfer (UTE‐MT) imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30144

Vancouver

Guo T, Song Y, Tong J, Jiao S, Shen C, Wang H, et al. Collagen degradation assessment with an in vitro rotator cuff tendinopathy model using multiparametric ultrashort‐TE magnetization transfer (UTE‐MT) imaging. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30144

BibTeX
@article{Guo2024,
  author = {Guo, Tan and Song, Yan and Tong, Jinlian and Jiao, Sheng and Shen, Cheng and Wang, Hong and Cui, Ju and Dai, Dapeng and Ma, Jie and Chen, Min},
  title = {Collagen degradation assessment with an in vitro rotator cuff tendinopathy model using multiparametric ultrashort‐TE magnetization transfer (UTE‐MT) imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30144}
}
Kostenlos starten →