SPINNED: Simulation‐based physics‐informed neural network for deconvolution of dynamic susceptibility contrast MRI perfusion data
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30095 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Muhammad Asaduddin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea. Hauptthemen laut MEDLINE: Neural Networks, Computer, Computer Simulation, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Korea Medical Device Development Fund, Hyundai Motor Chung Mong-Koo Foundation Scholarship Program, National Research Foundation of Korea.
Abstract (Originalsprache)
Purpose
To propose the simulation‐based physics‐informed neural network for deconvolution of dynamic susceptibility contrast (DSC) MRI (SPINNED) as an alternative for more robust and accurate deconvolution compared to existing methods.
Methods
The SPINNED method was developed by generating synthetic tissue residue functions and arterial input functions through mathematical simulations and by using them to create synthetic DSC MRI time series. The SPINNED model was trained using these simulated data to learn the underlying physical relation (deconvolution) between the DSC‐MRI time series and the arterial input functions. The accuracy and robustness of the proposed SPINNED method were assessed by comparing it with two common deconvolution methods in DSC MRI data analysis, circulant singular value decomposition, and Volterra singular value decomposition, using both simulation data and real patient data.
Results
The proposed SPINNED method was more accurate than the conventional methods across all SNR levels and showed better robustness against noise in both simulation and real patient data. The SPINNED method also showed much faster processing speed than the conventional methods.
Conclusion
These results support that the proposed SPINNED method can be a good alternative to the existing methods for resolving the deconvolution problem in DSC MRI. The proposed method does not require any separate ground‐truth measurement for training and offers additional benefits of quick processing time and coverage of diverse clinical scenarios. Consequently, it will contribute to more reliable, accurate, and rapid diagnoses in clinical applications compared with the previous methods including those based on supervised learning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea.
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
ORCID-Profile: Eung Yeop Kim, Sung-Hong Park
Förderung
- Korea Medical Device Development Fund
- Hyundai Motor Chung Mong-Koo Foundation Scholarship Program
- National Research Foundation of Korea
Zitieren
APA
Asaduddin, M., Kim, E. Y., & Park, S. H. (2024). SPINNED: Simulation‐based physics‐informed neural network for deconvolution of dynamic susceptibility contrast MRI perfusion data. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30095
Vancouver
Asaduddin M, Kim EY, Park SH. SPINNED: Simulation‐based physics‐informed neural network for deconvolution of dynamic susceptibility contrast MRI perfusion data. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30095
BibTeX
@article{Asaduddin2024,
author = {Asaduddin, Muhammad and Kim, Eung Yeop and Park, Sung-Hong},
title = {SPINNED: Simulation‐based physics‐informed neural network for deconvolution of dynamic susceptibility contrast MRI perfusion data},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30095}
}
EUVIMED