EUVIMEDEUVIMED entdecken
Open Access

Assessment of blood–brain barrier leakage and brain oxygenation in Connexin‐32 knockout mice with systemic neuroinflammation using pulse electron paramagnetic resonance imaging techniques

Boris Epel, Navin Viswakarma, Safa Hameed, Mona M Freidin, Charles K Abrams, Mrignayani Kotecha iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.29994 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Boris Epel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Blood-Brain Barrier, Neuroinflammatory Diseases. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The determination of blood–brain barrier (BBB) integrity and partial pressure of oxygen (pO 2 ) in the brain is of substantial interest in several neurological applications. This study aimed to assess the feasibility of using trityl OX071‐based pulse electron paramagnetic resonance imaging (pEPRI) to provide a quantitative estimate of BBB integrity and pO 2 maps in mouse brains as a function of neuroinflammatory disease progression.

Methods

Five Connexin‐32 (Cx32)–knockout (KO) mice were injected with lipopolysaccharide to induce neuroinflammation for imaging. Three wild‐type mice were also used to optimize the imaging procedure and as control animals. An additional seven Cx32‐KO mice were used to establish the BBB leakage of trityl using the colorimetric assay. All pEPRI experiments were performed using a preclinical instrument, JIVA‐25 (25 mT/720 MHz), at times t = 0, 4, and 6 h following lipopolysaccharide injection. Two pEPRI imaging techniques were used: (a) single‐point imaging for obtaining spatial maps to outline the brain and calculate BBB leakage using the signal amplitude, and (b) inversion‐recovery electron spin echo for obtaining pO 2 maps.

Results

A statistically significant change in BBB leakage was found using pEPRI with the progression of inflammation in Cx32 KO animals. However, the change in pO 2 values with the progression of inflammation for these animals was not statistically significant.

Conclusions

For the first time, we show the ability of pEPRI to provide pO 2 maps in mouse brains noninvasively, along with a quantitative assessment of BBB leakage. We expect this study to open new queries from the field to explore the pathology of many neurological diseases and provide a path to new treatments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood-Brain BarrierNeuroinflammatory DiseasesMiceAnimalsMice, KnockoutElectron Spin Resonance SpectroscopyLipopolysaccharidesBrainInflammationConnexins

Stichwörter der Autor:innen

blood–brain barrier integritybrain imagingneurodegenerative diseasesneuroinflammationoxygen imagingpulse EPRI

Substanzen

LipopolysaccharidesConnexins

Autor:innen und Institutionen

  • Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.
  • Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois, USA.
  • Department of Neurology and Rehabilitation, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA.

ORCID-Profile: Mrignayani Kotecha

Förderung

  • NCI NIH HHS

Zitieren

APA

Epel, B., Viswakarma, N., Hameed, S., Freidin, M. M., Abrams, C. K., & Kotecha, M. (2024). Assessment of blood–brain barrier leakage and brain oxygenation in Connexin‐32 knockout mice with systemic neuroinflammation using pulse electron paramagnetic resonance imaging techniques. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29994

Vancouver

Epel B, Viswakarma N, Hameed S, Freidin MM, Abrams CK, Kotecha M. Assessment of blood–brain barrier leakage and brain oxygenation in Connexin‐32 knockout mice with systemic neuroinflammation using pulse electron paramagnetic resonance imaging techniques. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29994

BibTeX
@article{Epel2024,
  author = {Epel, Boris and Viswakarma, Navin and Hameed, Safa and Freidin, Mona M and Abrams, Charles K and Kotecha, Mrignayani},
  title = {Assessment of blood–brain barrier leakage and brain oxygenation in Connexin‐32 knockout mice with systemic neuroinflammation using pulse electron paramagnetic resonance imaging techniques},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29994}
}
Kostenlos starten →