Hyperpolarized 13 C metabolic imaging of the human abdomen with spatiotemporal denoising
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.29985 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Tanner M Nickles und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology & Biomedical Imaging, University of California San Francisco, San Francisco, California, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Pyruvic Acid. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NCI NIH HHS, NIDDK NIH HHS.
Abstract (Originalsprache)
Purpose
Improving the quality and maintaining the fidelity of large coverage abdominal hyperpolarized (HP) 13 C MRI studies with a patch based global–local higher‐order singular value decomposition (GL‐HOVSD) spatiotemporal denoising approach.
Methods
Denoising performance was first evaluated using the simulated [1‐ 13 C]pyruvate dynamics at different noise levels to determine optimal k global and k local parameters. The GL‐HOSVD spatiotemporal denoising method with the optimized parameters was then applied to two HP [1‐ 13 C]pyruvate EPI abdominal human cohorts ( n = 7 healthy volunteers and n = 8 pancreatic cancer patients).
Results
The parameterization of k global = 0.2 and k local = 0.9 denoises abdominal HP data while retaining image fidelity when evaluated by RMSE. The k PX (conversion rate of pyruvate‐to‐metabolite, X = lactate or alanine) difference was shown to be 5) for downstream metabolites. In both human cohorts, there was a greater than nine‐fold gain in peak [1‐ 13 C]pyruvate, [1‐ 13 C]lactate, and [1‐ 13 C]alanine apparent SNR AUC . The improvement in metabolite SNR enabled a more robust quantification of k PL and k PA . After denoising, we observed a 2.1 ± 0.4 and 4.8 ± 2.5‐fold increase in the number of voxels reliably fit across abdominal FOVs for k PL and k PA quantification maps.
Conclusion
Spatiotemporal denoising greatly improves visualization of low SNR metabolites particularly [1‐ 13 C]alanine and quantification of [1‐ 13 C]pyruvate metabolism in large FOV HP 13 C MRI studies of the human abdomen.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology & Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
- UC Berkeley-UCSF Graduate Program in Bioengineering, San Francisco, California, USA.
ORCID-Profile: Tanner M Nickles, Yaewon Kim, Philip M Lee, Hsin-Yu Chen, Michael Ohliger, Peder E Z Larson, Daniel B Vigneron, Jeremy W Gordon
Förderung
- NIBIB NIH HHS
- NCI NIH HHS
- NIDDK NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Nickles, T. M., Kim, Y., Lee, P. M., Chen, H. Y., Ohliger, M., Bok, R. A., Wang, Z. J., Larson, P. E. Z., Vigneron, D. B., & Gordon, J. W. (2024). Hyperpolarized 13 C metabolic imaging of the human abdomen with spatiotemporal denoising. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29985
Vancouver
Nickles TM, Kim Y, Lee PM, Chen HY, Ohliger M, Bok RA, et al. Hyperpolarized 13 C metabolic imaging of the human abdomen with spatiotemporal denoising. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29985
BibTeX
@article{Nickles2024,
author = {Nickles, Tanner M and Kim, Yaewon and Lee, Philip M and Chen, Hsin-Yu and Ohliger, Michael and Bok, Robert A and Wang, Zhen J and Larson, Peder E Z and Vigneron, Daniel B and Gordon, Jeremy W},
title = {Hyperpolarized 13 C metabolic imaging of the human abdomen with spatiotemporal denoising},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.29985}
}
EUVIMED