Tensor‐valued diffusion MRI of human acute stroke
Magnetic Resonance in Medicine · 2024-05 · 91 (5) · 2126-2141
DOI: 10.1002/mrm.29975 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 29.12.2023. Verfasst von Mi Zhou und 13 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Ischemic Stroke, White Matter, Stroke. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Canada Research Chairs program, China Scholarship Council, Heart and Stroke Foundation of Canada.
Themen: Schlaganfall
Abstract (Originalsprache)
Purpose
Tensor‐valued diffusion encoding can disentangle orientation dispersion and subvoxel anisotropy, potentially offering insight into microstructural changes after cerebral ischemia. The purpose was to evaluate tensor‐valued diffusion MRI in human acute ischemic stroke, assess potential confounders from diffusion time dependencies, and compare to Monte Carlo diffusion simulations of axon beading.
Methods
Linear (LTE) and spherical (STE) b‐tensor encoding with inherently different effective diffusion times were acquired in 21 acute ischemic stroke patients between 3 and 57 h post‐onset at 3 T in 2.5 min. In an additional 10 patients, STE with 2 LTE yielding different effective diffusion times were acquired for comparison. Diffusional variance decomposition (DIVIDE) was used to estimate microscopic anisotropy (μFA), as well as anisotropic, isotropic, and total diffusional variance (MK A , MK I , MK T ). DIVIDE parameters, and diffusion tensor imaging (DTI)‐derived mean diffusivity and fractional anisotropy (FA) were compared in lesion versus contralateral white matter. Monte Carlo diffusion simulations of various cylindrical geometries for all b‐tensor protocols were used to interpret parameter measurements.
Results
MD was ˜40% lower in lesions for all LTE/STE protocols. The DIVIDE parameters varied with effective diffusion time: higher μFA and MK A in lesion versus contralateral white matter for STE with longer effective diffusion time LTE, whereas the shorter effective diffusion time LTE protocol yielded lower μFA and MK A in lesions. Both protocols, regardless of diffusion time, were consistent with simulations of greater beading amplitude and intracellular volume fraction.
Conclusion
DIVIDE parameters depend on diffusion time in acute stroke but consistently indicate neurite beading and larger intracellular volume fraction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
- Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada.
- Clinical Sciences Lund, Lund University, Lund, Scania, Sweden.
- Neurosurgery, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
- Neurology, University of Alberta, Edmonton, Alberta, Canada.
- School of Clinical Medicine, University of New South Wales, Sydney, New South Wales, Australia.
ORCID-Profile: Mi Zhou, Robert Stobbe, Markus Nilsson, Christian Beaulieu
Förderung
- Canada Research Chairs program
- China Scholarship Council
- Heart and Stroke Foundation of Canada
Zitieren
APA
Zhou, M., Stobbe, R., Szczepankiewicz, F., Budde, M., Buck, B., Kate, M., Lloret, M., Fairall, P., Butcher, K., Shuaib, A., Emery, D., Nilsson, M., Westin, C. F., & Beaulieu, C. (2024). Tensor‐valued diffusion MRI of human acute stroke. Magnetic Resonance in Medicine, 91(5), 2126-2141. https://doi.org/10.1002/mrm.29975
Vancouver
Zhou M, Stobbe R, Szczepankiewicz F, Budde M, Buck B, Kate M, et al. Tensor‐valued diffusion MRI of human acute stroke. Magnetic Resonance in Medicine. 2024;91(5):2126-2141. doi:10.1002/mrm.29975
BibTeX
@article{Zhou2024,
author = {Zhou, Mi and Stobbe, Robert and Szczepankiewicz, Filip and Budde, Matthew and Buck, Brian and Kate, Mahesh and Lloret, Mar and Fairall, Paige and Butcher, Ken and Shuaib, Ashfaq and Emery, Derek and Nilsson, Markus and Westin, Carl-Fredrik and Beaulieu, Christian},
title = {Tensor‐valued diffusion MRI of human acute stroke},
journal = {Magnetic Resonance in Medicine},
year = {2024},
volume = {91},
number = {5},
pages = {2126--2141},
doi = {10.1002/mrm.29975}
}
EUVIMED