Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Yongwan Lim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, Californ…. Hauptthemen laut MEDLINE: Larynx, Voice. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Science Foundation of Sri Lanka.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To demonstrate speech‐production real‐time MRI (RT‐MRI) using a contemporary 0.55T system, and to identify opportunities for improved performance compared with conventional field strengths.

Methods

Experiments were performed on healthy adult volunteers using a 0.55T MRI system with high‐performance gradients and a custom 8‐channel upper airway coil. Imaging was performed using spiral‐based balanced SSFP and gradient‐recalled echo (GRE) pulse sequences using a temporal finite‐difference constrained reconstruction. Speech‐production RT‐MRI was performed with three spiral readout durations (8.90, 5.58, and 3.48 ms) to determine trade‐offs with respect to articulator contrast, blurring, banding artifacts, and overall image quality.

Results

Both spiral GRE and bSSFP captured tongue boundary dynamics during rapid consonant‐vowel syllables. Although bSSFP provided substantially higher SNR in all vocal tract articulators than GRE, it suffered from banding artifacts at TR > 10.9 ms. Spiral bSSFP with the shortest readout duration (3.48 ms, TR = 5.30 ms) had the best image quality, with a 1.54‐times boost in SNR compared with an equivalent GRE sequence. Longer readout durations led to increased SNR efficiency and blurring in both bSSFP and GRE.

Conclusion

High‐performance 0.55T MRI systems can be used for speech‐production RT‐MRI. Spiral bSSFP can be used without suffering from banding artifacts in vocal tract articulators, provide better SNR efficiency, and have better image quality than what is typically achieved at 1.5 T or 3 T.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LarynxVoiceAdultHumansSpeechMagnetic Resonance ImagingTongueArtifacts

Stichwörter der Autor:innen

0.55 Treal-time MRIspeech productionspiralsusceptibility artifact

Autor:innen und Institutionen

  • Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.

ORCID-Profile: Yongwan Lim, Prakash Kumar, Krishna S Nayak

Förderung

  • National Science Foundation of Sri Lanka

Zitieren

APA

Lim, Y., Kumar, P., & Nayak, K. S. (2024). Speech production real‐time MRI at 0.55 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29843

Vancouver

Lim Y, Kumar P, Nayak KS. Speech production real‐time MRI at 0.55 T. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29843

BibTeX
@article{Lim2024,
  author = {Lim, Yongwan and Kumar, Prakash and Nayak, Krishna S},
  title = {Speech production real‐time MRI at 0.55 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29843}
}
Kostenlos starten →