Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure
Magnetic Resonance in Medicine · 2023
DOI: 10.1002/mrm.29751 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von D B Berry und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, University of California, San Diego, California, USA. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Muscle, Skeletal. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NIA NIH HHS, NIMH NIH HHS.
Abstract (Originalsprache)
Purpose
Preliminary study to determine whether double pulsed field gradient (PFG) diffusion MRI is sensitive to key features of muscle microstructure related to function.
Methods
The restricted diffusion profile of molecules in models of muscle microstructure derived from histology were systematically simulated using a numerical simulation approach. Diffusion tensor subspace imaging analysis of the diffusion signal was performed, and spherical anisotropy (SA) was calculated for each model. Linear regression was used to determine the predictive capacity of SA on the fiber area, fiber diameter, and surface area to volume ratio of the models. Additionally, a rat model of muscle hypertrophy was scanned using a single PFG and a double PFG pulse sequence, and the restricted diffusion measurements were compared with histological measurements of microstructure.
Results
Excellent agreement between SA and muscle fiber area ( r 2 = 0.71; p < 0.0001), fiber diameter ( r 2 = 0.83; p < 0.0001), and surface area to volume ratio ( r 2 = 0.97; p < 0.0001) in simulated models was found. In a scanned rat leg, the distribution of these microstructural features measured from histology was broad and demonstrated that there is a wide variance in the microstructural features observed, similar to the SA distributions. However, the distribution of fractional anisotropy measurements in the same tissue was narrow.
Conclusions
This study demonstrates that SA—a scalar value from diffusion tensor subspace imaging analysis—is highly sensitive to muscle microstructural features predictive of function. Furthermore, these techniques and analysis tools can be translated to real experiments in skeletal muscle. The increased dynamic range of SA compared with fractional anisotropy in the same tissue suggests increased sensitivity to detecting changes in tissue microstructure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, University of California, San Diego, California, USA.
- Department of Nanoengineering, University of California, San Diego, San Diego, California, USA.
- Center for Scientific Computation in Imaging, University of California, San Diego, San Diego, California, USA.
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA.
- Department of Medical Imaging, University of Arizona, Tucson, Arizona, USA.
- Department of Radiology, University of California, San Diego, California, USA.
Förderung
- NIH HHS
- NIA NIH HHS
- NIMH NIH HHS
- NIAMS NIH HHS
- National Institutes of Health
Zitieren
APA
Berry, D. B., Galinsky, V. L., Hutchinson, E. B., Galons, J. P., Ward, S. R., & Frank, L. R. (2023). Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29751
Vancouver
Berry DB, Galinsky VL, Hutchinson EB, Galons JP, Ward SR, Frank LR. Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29751
BibTeX
@article{Berry2023,
author = {Berry, D B and Galinsky, V L and Hutchinson, E B and Galons, J P and Ward, S R and Frank, L R},
title = {Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure},
journal = {Magnetic Resonance in Medicine},
year = {2023},
doi = {10.1002/mrm.29751}
}