EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Prediction of experimental cardiac magnetostimulation thresholds using pig‐specific body models

Valerie Klein iD, Mathias Davids iD, Livia Vendramini, Natalie G Ferris, Lothar R Schad, David E Sosnovik, Christopher T Nguyen iD, Lawrence L Wald iD, Bastien Guérin iD

Magnetic Resonance in Medicine · 2023-10 · 90 (4) · 1594-1609

DOI: 10.1002/mrm.29717 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 08.06.2023. Verfasst von Valerie Klein und 8 weiteren Autor:innen. Beteiligte Einrichtung: A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA. Hauptthemen laut MEDLINE: Electromagnetic Phenomena, Heart. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NHLBI NIH HHS, NIH HHS, NIGMS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Modern high‐amplitude gradient systems can be limited by the International Electrotechnical Commission 60601‐2‐33 cardiac stimulation (CS) limit, which was set in a conservative manner based on electrode experiments and E‐field simulations in uniform ellipsoidal body models. Here, we show that coupled electromagnetic‐electrophysiological modeling in detailed body and heart models can predict CS thresholds, suggesting that such modeling might lead to more detailed threshold estimates in humans. Specifically, we compare measured and predicted CS thresholds in eight pigs.

Methods

We created individualized porcine body models using MRI (Dixon for the whole body, CINE for the heart) that replicate the anatomy and posture of the animals used in our previous experimental CS study. We model the electric fields induced along cardiac Purkinje and ventricular muscle fibers and predict the electrophysiological response of these fibers, yielding CS threshold predictions in absolute units for each animal. Additionally, we assess the total modeling uncertainty through a variability analysis of the 25 main model parameters.

Results

Predicted and experimental CS thresholds agree within 19% on average (normalized RMS error), which is smaller than the 27% modeling uncertainty. No significant difference was found between the modeling predictions and experiments ( p < 0.05, paired t ‐test).

Conclusion

Predicted thresholds matched the experimental data within the modeling uncertainty, supporting the model validity. We believe that our modeling approach can be applied to study CS thresholds in humans for various gradient coils, body shapes/postures, and waveforms, which is difficult to do experimentally.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electromagnetic PhenomenaHeartHumansSwineAnimalsMagnetic Resonance ImagingHeart VentriclesElectricity

Stichwörter der Autor:innen

MRI gradient field bioeffectscardiac stimulationelectromagnetic exposure safetymagnetostimulation thresholds

Autor:innen und Institutionen

  • A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
  • Harvard Medical School, Boston, Massachusetts, USA.
  • Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Heidelberg, Germany.
  • Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts, USA.
  • Mannheim Institute for Intelligent Systems in Medicine, Heidelberg University, Heidelberg, Germany.
  • Cardiovascular Research Center, Cardiology Division, Massachusetts General Hospital, Charlestown, Massachusetts, USA.

ORCID-Profile: Valerie Klein, Mathias Davids, Christopher T Nguyen, Lawrence L Wald, Bastien Guérin

Förderung

  • NHLBI NIH HHS
  • NIH HHS
  • NIGMS NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Klein, V., Davids, M., Vendramini, L., Ferris, N. G., Schad, L. R., Sosnovik, D. E., Nguyen, C. T., Wald, L. L., & Guérin, B. (2023). Prediction of experimental cardiac magnetostimulation thresholds using pig‐specific body models. Magnetic Resonance in Medicine, 90(4), 1594-1609. https://doi.org/10.1002/mrm.29717

Vancouver

Klein V, Davids M, Vendramini L, Ferris NG, Schad LR, Sosnovik DE, et al. Prediction of experimental cardiac magnetostimulation thresholds using pig‐specific body models. Magnetic Resonance in Medicine. 2023;90(4):1594-1609. doi:10.1002/mrm.29717

BibTeX
@article{Klein2023,
  author = {Klein, Valerie and Davids, Mathias and Vendramini, Livia and Ferris, Natalie G and Schad, Lothar R and Sosnovik, David E and Nguyen, Christopher T and Wald, Lawrence L and Guérin, Bastien},
  title = {Prediction of experimental cardiac magnetostimulation thresholds using pig‐specific body models},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  volume = {90},
  number = {4},
  pages = {1594--1609},
  doi = {10.1002/mrm.29717}
}
Kostenlos starten →