Cardiac q‐space trajectory imaging by motion‐compensated tensor‐valued diffusion encoding in human heart in vivo
Magnetic Resonance in Medicine · 2023
DOI: 10.1002/mrm.29637 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Irvin Teh und 12 weiteren Autor:innen. Beteiligte Einrichtung: Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging, Heart. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation, Department of Health, Wellcome Trust.
Abstract (Originalsprache)
Purpose
Tensor‐valued diffusion encoding can probe more specific features of tissue microstructure than what is available by conventional diffusion weighting. In this work, we investigate the technical feasibility of tensor‐valued diffusion encoding at high b ‐values with q‐space trajectory imaging (QTI) analysis, in the human heart in vivo.
Methods
Ten healthy volunteers were scanned on a 3T scanner. We designed time‐optimal gradient waveforms for tensor‐valued diffusion encoding (linear and planar) with second‐order motion compensation. Data were analyzed with QTI. Normal values and repeatability were investigated for the mean diffusivity (MD), fractional anisotropy (FA), microscopic FA (μFA), isotropic, anisotropic and total mean kurtosis (MKi, MKa, and MKt), and orientation coherence ( C c ). A phantom, consisting of two fiber blocks at adjustable angles, was used to evaluate sensitivity of parameters to orientation dispersion and diffusion time.
Results
QTI data in the left ventricular myocardium were MD = 1.62 ± 0.07 μm 2 /ms, FA = 0.31 ± 0.03, μFA = 0.43 ± 0.07, MKa = 0.20 ± 0.07, MKi = 0.13 ± 0.03, MKt = 0.33 ± 0.09, and C c = 0.56 ± 0.22 (mean ± SD across subjects). Phantom experiments showed that FA depends on orientation dispersion, whereas μFA was insensitive to this effect.
Conclusion
We demonstrated the first tensor‐valued diffusion encoding and QTI analysis in the heart in vivo, along with first measurements of myocardial μFA, MKi, MKa, and C c . The methodology is technically feasible and provides promising novel biomarkers for myocardial tissue characterization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
- Leeds Teaching Hospitals Trust, Leeds, UK.
- Faculty of Industrial Design Engineering, Delft University of Technology, Delft, Netherlands.
- Center for Medical Image Computing, Department of Medical Physics & Biomedical Engineering and Department of Neuroinflammation, University College London, London, UK.
- Astrea Bioseparation, Comberton, UK.
- Bioxydyn Limited, Manchester, UK.
ORCID-Profile: Irvin Teh, Jordan H Boyle, Fenglei Zhou, Ana-Maria Poenar, Noor Sharrack, Richard J Foster, Nadira Y Yuldasheva, Geoff J M Parker, Erica Dall'Armellina, Sven Plein, Jürgen E Schneider, Filip Szczepankiewicz
Förderung
- British Heart Foundation
- Department of Health
- Wellcome Trust
- European Society of Cardiology
- Cancerfonden
- Vetenskapsrådet
Zitieren
APA
Teh, I., Shelley, D., Boyle, J. H., Zhou, F., Poenar, A. M., Sharrack, N., Foster, R. J., Yuldasheva, N. Y., Parker, G. J. M., Dall'Armellina, E., Plein, S., Schneider, J. E., & Szczepankiewicz, F. (2023). Cardiac q‐space trajectory imaging by motion‐compensated tensor‐valued diffusion encoding in human heart in vivo. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29637
Vancouver
Teh I, Shelley D, Boyle JH, Zhou F, Poenar AM, Sharrack N, et al. Cardiac q‐space trajectory imaging by motion‐compensated tensor‐valued diffusion encoding in human heart in vivo. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29637