EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cardiac q‐space trajectory imaging by motion‐compensated tensor‐valued diffusion encoding in human heart in vivo

Irvin Teh iD, David Shelley, Jordan H Boyle iD, Fenglei Zhou iD, Ana-Maria Poenar iD, Noor Sharrack iD, Richard J Foster iD, Nadira Y Yuldasheva iD, Geoff J M Parker iD, Erica Dall'Armellina iD, Sven Plein iD, Jürgen E Schneider iD und 1 weitere

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29637 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Irvin Teh und 12 weiteren Autor:innen. Beteiligte Einrichtung: Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging, Heart. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation, Department of Health, Wellcome Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Tensor‐valued diffusion encoding can probe more specific features of tissue microstructure than what is available by conventional diffusion weighting. In this work, we investigate the technical feasibility of tensor‐valued diffusion encoding at high b ‐values with q‐space trajectory imaging (QTI) analysis, in the human heart in vivo.

Methods

Ten healthy volunteers were scanned on a 3T scanner. We designed time‐optimal gradient waveforms for tensor‐valued diffusion encoding (linear and planar) with second‐order motion compensation. Data were analyzed with QTI. Normal values and repeatability were investigated for the mean diffusivity (MD), fractional anisotropy (FA), microscopic FA (μFA), isotropic, anisotropic and total mean kurtosis (MKi, MKa, and MKt), and orientation coherence ( C c ). A phantom, consisting of two fiber blocks at adjustable angles, was used to evaluate sensitivity of parameters to orientation dispersion and diffusion time.

Results

QTI data in the left ventricular myocardium were MD = 1.62 ± 0.07 μm 2 /ms, FA = 0.31 ± 0.03, μFA = 0.43 ± 0.07, MKa = 0.20 ± 0.07, MKi = 0.13 ± 0.03, MKt = 0.33 ± 0.09, and C c = 0.56 ± 0.22 (mean ± SD across subjects). Phantom experiments showed that FA depends on orientation dispersion, whereas μFA was insensitive to this effect.

Conclusion

We demonstrated the first tensor‐valued diffusion encoding and QTI analysis in the heart in vivo, along with first measurements of myocardial μFA, MKi, MKa, and C c . The methodology is technically feasible and provides promising novel biomarkers for myocardial tissue characterization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Tensor ImagingHeartHumansDiffusion Magnetic Resonance ImagingMyocardiumHeart VentriclesAnisotropy

Stichwörter der Autor:innen

cardiac microstructurediffusion tensor imagingmotion-compensated diffusion encodingq-space trajectory imagingtensor-valued diffusion encodingtissue characterization

Autor:innen und Institutionen

  • Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Leeds Teaching Hospitals Trust, Leeds, UK.
  • Faculty of Industrial Design Engineering, Delft University of Technology, Delft, Netherlands.
  • Center for Medical Image Computing, Department of Medical Physics & Biomedical Engineering and Department of Neuroinflammation, University College London, London, UK.
  • Astrea Bioseparation, Comberton, UK.
  • Bioxydyn Limited, Manchester, UK.

ORCID-Profile: Irvin Teh, Jordan H Boyle, Fenglei Zhou, Ana-Maria Poenar, Noor Sharrack, Richard J Foster, Nadira Y Yuldasheva, Geoff J M Parker, Erica Dall'Armellina, Sven Plein, Jürgen E Schneider, Filip Szczepankiewicz

Förderung

  • British Heart Foundation
  • Department of Health
  • Wellcome Trust
  • European Society of Cardiology
  • Cancerfonden
  • Vetenskapsrådet

Zitieren

APA

Teh, I., Shelley, D., Boyle, J. H., Zhou, F., Poenar, A. M., Sharrack, N., Foster, R. J., Yuldasheva, N. Y., Parker, G. J. M., Dall'Armellina, E., Plein, S., Schneider, J. E., & Szczepankiewicz, F. (2023). Cardiac q‐space trajectory imaging by motion‐compensated tensor‐valued diffusion encoding in human heart in vivo. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29637

Vancouver

Teh I, Shelley D, Boyle JH, Zhou F, Poenar AM, Sharrack N, et al. Cardiac q‐space trajectory imaging by motion‐compensated tensor‐valued diffusion encoding in human heart in vivo. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29637

BibTeX
@article{Teh2023,
  author = {Teh, Irvin and Shelley, David and Boyle, Jordan H and Zhou, Fenglei and Poenar, Ana-Maria and Sharrack, Noor and Foster, Richard J and Yuldasheva, Nadira Y and Parker, Geoff J M and Dall'Armellina, Erica and Plein, Sven and Schneider, Jürgen E and Szczepankiewicz, Filip},
  title = {Cardiac q‐space trajectory imaging by motion‐compensated tensor‐valued diffusion encoding in human heart in vivo},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29637}
}
Kostenlos starten →