EUVIMEDEUVIMED entdecken
Open Access

Vascular space occupancy asymmetric spin echo ( VASO‐ASE ) for non‐invasive quantification of cerebral oxygen extraction fraction

Spencer L Waddle iD, Maria Garza, Chunwei Ying iD, L Taylor Davis, Lori C Jordan, Hongyu An iD, Manus J Donahue

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29618 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Spencer L Waddle und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Hauptthemen laut MEDLINE: Oxygen, Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NICHD NIH HHS, NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Asymmetric spin echo (ASE) MRI is a method for measuring regional oxygen extraction fraction (OEF); however, extravascular tissue models have been shown to under‐estimate OEF. The hypothesis investigated here is that the addition of a vascular‐space‐occupancy (VASO) pre‐pulse will more fully suppress blood water signal and provide global OEF values more consistent with physiological expectation and 15 O positron emission tomography (PET)‐validated T 2 ‐relaxation‐under‐spin‐tagging (TRUST) OEF measures.

Methods

Healthy adults ( n = 14; age = 27.7 ± 5.2 y; sex = 7/7 male/female) were scanned at 3.0T. Multi‐echo ASE without inter‐readout refocusing (ASE RF− ), multi‐echo ASE with inter‐readout refocusing (ASE RF+ ), and single‐echo VASO‐ASE were acquired twice each with common spatial resolution = 3.44 × 3.44 × 3.0 mm and τ = 0–20 ms (interval = 0.5 ms). TRUST was acquired twice sequentially for independent global OEF assessment ( τ CPMG = 10 ms; effective TEs = 0, 40, 80, and 160 ms; spatial resolution = 3.4 × 3.4 × 5 mm). OEF intraclass‐correlation‐coefficients (ICC), summary statistics, and group‐wise differences were assessed (Wilcoxon rank‐sum; significance: two‐sided p < 0.05).

Results

ASE RF+ (OEF = 36.8 ± 1.9%) and VASO‐ASE (OEF = 34.4 ± 2.3%) produced OEF values similar to TRUST (OEF = 36.5 ± 4.6%, human calibration model; OEF = 32.7 ± 4.9%, bovine calibration model); however, ASE RF− yielded lower OEF (OEF = 26.1 ± 1.0%; p < 0.01) relative to TRUST. VASO‐ASE (ICC = 0.61) yielded lower ICC compared to other ASE variants (ICC >0.89).

Conclusion

VASO‐ASE and TRUST provide similar OEF values; however, VASO‐ASE spatial coverage and repeatability improvements are required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OxygenMagnetic Resonance ImagingAdultHumansMaleFemaleAnimalsCattleYoung AdultHeart RateBrainCerebrovascular CirculationOxygen Consumption

Stichwörter der Autor:innen

T2-relaxation-under-spin-taggingVASOasymmetric spin echooxygen extraction fractionqBOLD

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA.
  • Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Department of Pediatrics, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Department of Psychiatry and Behavioral Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.

ORCID-Profile: Spencer L Waddle, Chunwei Ying, Hongyu An

Förderung

  • NINDS NIH HHS
  • NICHD NIH HHS
  • NHLBI NIH HHS
  • NCI NIH HHS
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Waddle, S. L., Garza, M., Ying, C., Davis, L. T., Jordan, L. C., An, H., & Donahue, M. J. (2023). Vascular space occupancy asymmetric spin echo ( VASO‐ASE ) for non‐invasive quantification of cerebral oxygen extraction fraction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29618

Vancouver

Waddle SL, Garza M, Ying C, Davis LT, Jordan LC, An H, et al. Vascular space occupancy asymmetric spin echo ( VASO‐ASE ) for non‐invasive quantification of cerebral oxygen extraction fraction. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29618

BibTeX
@article{Waddle2023,
  author = {Waddle, Spencer L and Garza, Maria and Ying, Chunwei and Davis, L Taylor and Jordan, Lori C and An, Hongyu and Donahue, Manus J},
  title = {Vascular space occupancy asymmetric spin echo ( VASO‐ASE ) for non‐invasive quantification of cerebral oxygen extraction fraction},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29618}
}
Kostenlos starten →