Optimal Experimental Design for Fast and Accurate Relaxation Time Measurements in Magnetic Resonance
Magnetic Resonance in Chemistry · 2026-12 · 64 (12) · 1001-1012
DOI: 10.1002/mrc.70140 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Chemistry, online erschienen am 10.09.2026. Verfasst von Natalie E Klein und 4 weiteren Autor:innen. Beteiligte Einrichtung: Statistics, Los Alamos National Laboratory, Los Alamos, New Mexico, USA. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Laboratory Directed Research and Development.
Abstract (Originalsprache)
Relaxation time constants in magnetic resonance are sensitive probes of molecular structure and dynamics and are critical for achieving spatial contrast in imaging, but measuring relaxation times is generally far more time‐consuming than traditional 1D spectroscopic experiments. Furthermore, the accuracy of the measured constants depends on numerous experimental factors. Currently, there are several available methods for designing a relaxation measurement (e.g., linear or logarithmic time spacing), but it is often unclear which method is preferable, how to select the minimum and maximum time points, or how many increments should be used, with all choices affecting the experimental time and the accuracy. Here, we consider optimal experimental designs and show that they maximize information per measurement, leading to more precise estimates for a specified relaxation model while in favorable cases reducing the number of measurements, and potentially the experimental time, required to achieve comparable precision relative to conventional sampling designs. Theoretical results on optimal experimental designs are explored both via simulation studies (for both mono‐ and multiexponential models) and via experiments for monoexponential measurements on nuclear magnetic resonance systems. We emphasize that the resulting designs are optimal for parameter estimation under an assumed model rather than for model discovery or relaxation‐time distribution recovery. We conclude with practical guidelines for improved experimental design for relaxation‐time measurements in magnetic resonance while clarifying the limitations of model‐based optimal design.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Statistics, Los Alamos National Laboratory, Los Alamos, New Mexico, USA.
- Materials Physics & Applications - Quantum, Los Alamos National Laboratory, Los Alamos, New Mexico, USA.
- Department of Statistics and Data Sciences, University of Texas at Austin, Austin, Texas, USA.
- Nondestructive Testing & Evaluation, Los Alamos National Laboratory, Los Alamos, New Mexico, USA.
ORCID-Profile: Natalie E Klein
Förderung
- Laboratory Directed Research and Development
Zitieren
APA
Klein, N. E., Altenhof, A. R., Day, A. J., Espy, M. A., & Malone, M. W. (2026). Optimal Experimental Design for Fast and Accurate Relaxation Time Measurements in Magnetic Resonance. Magnetic Resonance in Chemistry, 64(12), 1001-1012. https://doi.org/10.1002/mrc.70140
Vancouver
Klein NE, Altenhof AR, Day AJ, Espy MA, Malone MW. Optimal Experimental Design for Fast and Accurate Relaxation Time Measurements in Magnetic Resonance. Magnetic Resonance in Chemistry. 2026;64(12):1001-1012. doi:10.1002/mrc.70140
BibTeX
@article{Klein2026,
author = {Klein, Natalie E and Altenhof, Adam R and Day, Amber J and Espy, Michelle A and Malone, Michael W},
title = {Optimal Experimental Design for Fast and Accurate Relaxation Time Measurements in Magnetic Resonance},
journal = {Magnetic Resonance in Chemistry},
year = {2026},
volume = {64},
number = {12},
pages = {1001--1012},
doi = {10.1002/mrc.70140}
}
EUVIMED