EUVIMEDEUVIMED entdecken
Crossref

Rapid coronary computed tomography angiography‐derived fractional flow reserve: A feasibility study for on‐site assessment

George C Bourantas, Konstantinos Katsanos, Foivos Bekiris, Karol Miller, Grigoris Karamasis, Michail Papafaklis, Grigorios Tsigkas, Periklis Davlouros, George C Kagadis iD

Medical Physics · 2026-11 · 53 (11)

DOI: 10.1002/mp.70754 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 11.11.2026. Verfasst von George C Bourantas und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Computed Tomography Angiography, Coronary Angiography. Die Arbeit nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Fractional flow reserve (FFR) is the reference standard for physiological assessment of coronary artery stenosis severity, but invasive measurement requires catheterization and hyperemic agents. Coronary computed tomography angiography (CCTA)‐derived FFR offers a non‐invasive alternative, though existing approaches based on computational fluid dynamics (CFD) are computationally intensive and impractical for on‐site clinical use.

Purpose

To evaluate the feasibility of rapidly estimating FFR from CCTA using three mathematical, centerline‐based computational methodologies. This study investigates whether pressure‐drop formulations relying solely on coronary geometric information can provide rapid FFR estimates suitable for potential on‐site clinical application, without the need for computationally intensive fluid dynamics simulations.

Methods

Three CCTA‐derived FFR methodologies were evaluated: fixed Fractional Flow Reserve (fFFR3D), mathematical virtual Functional Assessment Index (mvFAI3D), and tomographic Fractional Flow Reserve (tomoFFR). Each method uses the patient mean arterial pressure (MAP) along with the coronary centerline geometry to characterize vessel dimensions and estimate pressure loss under hyperemic conditions. fFFR3D assumes a fixed hyperaemic blood velocity of 0.35 m/s; mvFAI3D extends the virtual Functional Assessment Index (vFAI) using a mathematical pressure‐drop formulation; and tomoFFR estimates hyperaemic flow and pressure loss using a baseline fixed‐velocity approach. Fourteen coronary vessels from a publicly available dataset with reference invasive FFR measurements were analyzed. Predicted FFR values were compared with clinical measurements (wire measured FFR), with emphasis on classification relative to the clinical threshold of and on computational time.

Results

Relative to the FFR = 0.80 threshold, fFFR3D and tomoFFR correctly classified 12 of the 14 vessels (85.7%) and mvFAI3D correctly classified 11 of the 14 vessels (78.6%). Given the limited sample size, no definitive conclusions regarding diagnostic accuracy or generalizability can be drawn. Nevertheless, the results demonstrate the feasibility of applying mathematical pressure‐drop models directly to CCTA‐derived coronary centerlines. Once centerlines were available, all three approaches required less than 1 s to calculate FFR, enabling substantially faster estimation than conventional CFD‐based approaches and supporting potential integration into on‐site CCTA analysis workflows.

Conclusions

These findings demonstrate the feasibility of rapid, centerline‐based CCTA‐derived FFR estimation using mathematical models of coronary pressure loss. Sub‐second computational time, combined with the availability of automated AI‐based coronary centerline extraction and physician correction in contemporary CCTA workstations, provides a potential pathway toward on‐site FFR assessment during routine CT interpretation. Larger prospective, multicenter studies with invasive FFR reference measurements are required to establish diagnostic accuracy, reproducibility, and clinical robustness prior to clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractional Flow Reserve, MyocardialComputed Tomography AngiographyCoronary AngiographyFeasibility StudiesHumansTime FactorsImage Processing, Computer-AssistedHydrodynamics

Stichwörter der Autor:innen

CCTAcenterlinecoronary stenosisfractional flow reservemathematical modelingpressure drop

Autor:innen und Institutionen

  • Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece.
  • Intelligent Systems for Medicine Laboratory, School of Engineering, The University of Western Australia, Perth, Western Australia.
  • Department of Interventional Radiology, School of Medicine, University of Patras, Patras, Greece.
  • Medlytic Labs Inc, Patras, Greece.
  • Attikon University Hospital, National and Kapodistrian University of Athens, School of Medicine, Athens, Greece.
  • Department of Cardiology, School of Medicine, University of Patras, Patras, Greece.

ORCID-Profile: George C Kagadis

Zitieren

APA

Bourantas, G. C., Katsanos, K., Bekiris, F., Miller, K., Karamasis, G., Papafaklis, M., Tsigkas, G., Davlouros, P., & Kagadis, G. C. (2026). Rapid coronary computed tomography angiography‐derived fractional flow reserve: A feasibility study for on‐site assessment. Medical Physics, 53(11). https://doi.org/10.1002/mp.70754

Vancouver

Bourantas GC, Katsanos K, Bekiris F, Miller K, Karamasis G, Papafaklis M, et al. Rapid coronary computed tomography angiography‐derived fractional flow reserve: A feasibility study for on‐site assessment. Medical Physics. 2026;53(11). doi:10.1002/mp.70754

BibTeX
@article{Bourantas2026,
  author = {Bourantas, George C and Katsanos, Konstantinos and Bekiris, Foivos and Miller, Karol and Karamasis, Grigoris and Papafaklis, Michail and Tsigkas, Grigorios and Davlouros, Periklis and Kagadis, George C},
  title = {Rapid coronary computed tomography angiography‐derived fractional flow reserve: A feasibility study for on‐site assessment},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {11},
  doi = {10.1002/mp.70754}
}
Kostenlos starten →