Single‐time‐point renal dosimetry for [ 177 Lu]Lu‐PSMA‐617: Incorporating multi‐cycle population data using nonlinear mixed‐effects models
Medical Physics · 2026
DOI: 10.1002/mp.70736 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2026. Verfasst von Indra Budiansah und 6 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics and Biophysics Division, Physics Department, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, Indonesia. Hauptthemen laut MEDLINE: Radiometry, Heterocyclic Compounds, 1-Ring, Dipeptides, Lutetium. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Indonesian Endowment Fund for Education (LPDP), DAAD, Deutscher Akademischer Austauschdienst.
Abstract (Originalsprache)
Background
Single‐time‐point (STP) dosimetry using nonlinear mixed‐effects (NLME) modeling has emerged as a promising approach, with recent studies demonstrating high accuracy. This framework enables estimation of the time‐integrated activity coefficient (TIAC) from a single imaging time point and, consequently, prediction of absorbed dose for subsequent therapy cycles. However, the use of multi‐cycle population data to support NLME‐based STP dosimetry has not yet been systematically evaluated.
Purpose
This study aimed to evaluate whether incorporating multi‐cycle population data into an NLME framework improves agreement between STP‐derived TIACs and all‐time‐point (ATP)‐derived model‐based reference TIACs in renal dosimetry.
Methods
Renal biokinetic data [ 177 Lu]Lu‐PSMA‐617 were collected from 10 patients over two therapy cycles, with both kidneys analyzed, yielding 40 renal datasets. In both cycles, SPECT/CT imaging was performed at five time points. A literature‐based structural function was used in the NLME modeling to incorporate inter‐individual variability, inter‐cycle variability, and variability between left and right kidney positions. Goodness‐of‐fit was evaluated based on visual inspection, relative standard errors (RSEs) < 50%, and the absolute value of the off‐diagonal elements in the correlation matrix < 0.8. TIACs derived from ATP fitting were used as the reference (rTIACs). STP fitting was performed using the leave‐one‐out method across defined scenarios. The TIACs derived from STP fitting were designated as STP TIACs (sTIACs). The accuracy of sTIACs in predicting rTIACs was assessed using relative deviations (RDs) and mean absolute percentage error (MAPE).
Results
The model fits satisfied all predefined goodness‐of‐fit criteria. STP dosimetry using the multi‐cycle dataset offered greater flexibility in time‐point combinations, leading to MAPEs < 10%. Additionally, an improvement in early‐time‐point STP dosimetry was observed when using multi‐cycle data.
Conclusions
Incorporating multi‐cycle data into NLME‐based STP dosimetry reduced extreme RDs, increased flexibility in feasible time‐point combinations, and improved early‐time‐point STP performance in this small two‐cycle cohort.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Medical Physics and Biophysics Division, Physics Department, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, Indonesia.
- Medical Radiation Physics, Department of Nuclear Medicine, Ulm University, Ulm, Germany.
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, The Netherlands.
- Röntgeninstitut Düsseldorf, Düsseldorf, Germany.
- Department of Radiation Oncology, Erasmus Medical Center, Rotterdam, The Netherlands.
Förderung
- Indonesian Endowment Fund for Education (LPDP)
- DAAD
- Deutscher Akademischer Austauschdienst
Zitieren
APA
Budiansah, I., Peters, S. M. B., Privé, B., Nagarajah, J., Konijnenberg, M. W., Glatting, G., & Hardiansyah, D. (2026). Single‐time‐point renal dosimetry for [ 177 Lu]Lu‐PSMA‐617: Incorporating multi‐cycle population data using nonlinear mixed‐effects models. Medical Physics. https://doi.org/10.1002/mp.70736
Vancouver
Budiansah I, Peters SMB, Privé B, Nagarajah J, Konijnenberg MW, Glatting G, et al. Single‐time‐point renal dosimetry for [ 177 Lu]Lu‐PSMA‐617: Incorporating multi‐cycle population data using nonlinear mixed‐effects models. Medical Physics. 2026. doi:10.1002/mp.70736
BibTeX
@article{Budiansah2026,
author = {Budiansah, Indra and Peters, Steffie M B and Privé, Bastiaan and Nagarajah, James and Konijnenberg, Mark W and Glatting, Gerhard and Hardiansyah, Deni},
title = {Single‐time‐point renal dosimetry for [ 177 Lu]Lu‐PSMA‐617: Incorporating multi‐cycle population data using nonlinear mixed‐effects models},
journal = {Medical Physics},
year = {2026},
doi = {10.1002/mp.70736}
}
EUVIMED