Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 03.08.2026. Verfasst von Dengyun Mu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China. Hauptthemen laut MEDLINE: Proton Therapy, Positron-Emission Tomography, Imaging, Three-Dimensional. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Natural Science Foundation of China, Open Research Fund of Hubei Key Laboratory of Precision Radiation Oncology, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In‐beam positron emission tomography (PET) integrates dedicated detectors into proton therapy systems, enabling real‐time acquisition of proton‐induced positron‐emitting activity. By pre‐delivering a subset of single‐energy proton spots as probes, in‐beam PET has the potential to support online proton range verification and may inform subsequent spot delivery. However, the limited acquisition time and low yields of positron emitters result in noisy reconstructed images, and the open geometry of dual‐panel PET further introduces stretching artifacts.

Purpose

To address these issues, this study proposed a 3D U‐Net‐based post‐processing method to enhance in‐beam PET image quality and evaluated its feasibility through Monte Carlo simulations and preliminary experimental validation.

Methods

Thirteen head computed tomography (CT) phantoms were irradiated with horizontally and vertically incident single‐energy probes, representing two scenarios in which beams passed through relatively homogeneous and heterogeneous tissues. A phantom‐level split was used, with seven CT phantoms for training, two for validation, and four held‐out CT phantoms for testing. Proton probes in 3×3, 5×5, 7×7, and 9×9 spot patterns were simulated, with each spot delivering 2×10 7 protons. In‐beam PET acquisition was performed for 30 s. Unfiltered reconstructed PET images were used as network inputs, and ground‐truth activity distributions served as labels. Gaussian‐filtered PET images served as the baseline for performance evaluation. Image quality was quantified by peak signal‐to‐noise ratio (PSNR) and structural similarity index (SSIM), and proton range verification accuracy was evaluated by absolute range error (ARE). Additional simulations with CT density perturbations were conducted to evaluate sensitivity to proton range shifts. Preliminary experimental validation was performed using an all‐digital PET prototype and polymethyl methacrylate (PMMA) phantoms.

Results

For horizontal beams, median PSNR values increased from 21.4–23.9 to 35.2–37.4, median SSIM values increased from 0.450–0.621 to 0.906–0.961, and median ARE values decreased from 1.05–1.18 mm to 0.52–0.73 mm. For vertical beams, median PSNR values improved from 21.9–23.2 to 29.2–34.1, median SSIM values improved from 0.480–0.560 to 0.745–0.895, and median ARE values decreased from 1.80–2.40 mm to 1.50–1.73 mm. The proposed method also demonstrated improved sensitivity to simulated range shifts and consistent improvements on experimental PET data.

Conclusion

These findings demonstrate the preliminary feasibility of using 3D U‐Net‐based post‐processing to enhance dual‐panel in‐beam PET image quality and improve PET‐based proton range verification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyPositron-Emission TomographyImaging, Three-DimensionalPhantoms, ImagingMonte Carlo MethodSignal-To-Noise Ratio

Stichwörter der Autor:innen

deep learningpositron emission tomography (PET)proton therapy monitoring

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China.
  • Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China.
  • Wuhan National Laboratory of Optoelectronics, Wuhan, China.
  • Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, China.
  • School of Software Engineering, Huazhong University of Science and Technology, Wuhan, China.

Förderung

  • Natural Science Foundation of China
  • Open Research Fund of Hubei Key Laboratory of Precision Radiation Oncology
  • National Natural Science Foundation of China

Zitieren

APA

Mu, D., Qi, P., Qiu, A., Liu, Q., Ma, Q., Xiao, P., Wan, L., Li, B., Deng, J., Qiu, B., Yang, Z., & Xie, Q. (2026). Improving dual‐panel in‐beam PET imaging for proton therapy monitoring using 3D U‐Net. Medical Physics, 53(8). https://doi.org/10.1002/mp.70609

Vancouver

Mu D, Qi P, Qiu A, Liu Q, Ma Q, Xiao P, et al. Improving dual‐panel in‐beam PET imaging for proton therapy monitoring using 3D U‐Net. Medical Physics. 2026;53(8). doi:10.1002/mp.70609

BibTeX
@article{Mu2026,
  author = {Mu, Dengyun and Qi, Pengyuan and Qiu, Ao and Liu, Qi and Ma, Qiuhui and Xiao, Peng and Wan, Lin and Li, Bingxuan and Deng, Jianchun and Qiu, Bensheng and Yang, Zhiyong and Xie, Qingguo},
  title = {Improving dual‐panel in‐beam PET imaging for proton therapy monitoring using 3D U‐Net},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {8},
  doi = {10.1002/mp.70609}
}
Kostenlos starten →