Diffusing alpha‐emitters radiation therapy dosimetry: Geant4 multi‐stage Monte Carlo modeling of sources
Medical Physics · 2026-06 · 53 (6)
DOI: 10.1002/mp.70494 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 11.06.2026. Verfasst von Mitchell D Lielkajis und 6 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia. Hauptthemen laut MEDLINE: Monte Carlo Method, Alpha Particles, Radiometry, Brachytherapy. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Australian Government Research Training Program Scholarship.
Abstract (Originalsprache)
Background
Diffusing alpha‐emitters Radiation Therapy (DaRT) is a brachytherapy treatment modality that utilizes the diffusing progeny of to treat solid tumors with therapeutic alpha radiation. The treatment is very complex, with comprehensive dosimetry, micro‐ and nanodosimetry, and detector studies requiring temporal modelling of the entire decay chain, diffusion, energy‐transfer physics, and the implementation of boundary conditions for both desorbed and source‐bound nuclides.
Purpose
To present and validate a 3D Monte Carlo (MC) model that combines the full decay chain, radionuclide diffusion, and particle energy‐transfer physics, to enable temporal DaRT dosimetry for both source‐bound and diffusing nuclides.
Methods
Using the Geant4 toolkit, a multi‐stage Monte Carlo model (MSMCM) was developed to combine radioactive decay, Brownian motion, and particle energy‐transfer physics into a single framework. Using this framework we performed three simulations, with different boundary condition variants, for point, single, and multi‐source model configurations, with the dose distributions validated against published analytical models. The MSMCM's potential application for use in multi‐source in‐vivo detector analyses was also assessed.
Results
The MSMCM was successfully able to produce spatial and temporal dose distributions for all source types: point, single, and multi‐source. Additionally, for the single source model, we produced full‐spectrum dosimetry, dose‐buildup, and dose‐rate curves over clinically relevant timeframes. Comparing the MSMCMs benchmark models, we found that the measured dose depositions of point‐ and radial‐source scenarios were within 5%. We also found that boundary conditions had a marked impact on the axial depth‐dose for realistic source geometries.
Conclusions
The MSMCM provides a flexible particle‐by‐particle solution to modelling DaRT, producing spatial and temporal dosimetry consistent with current analytical models. Given the MSMCM's capacity to model the complete decay chain, diffusion, track‐level energy depositions, and complex boundaries in a single framework, it is suitable for micro‐ and nanodosimetry, multi‐source in‐vivo dosimetry, and detector analysis studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia.
- St George Cancer Care Centre, The St George Hospital, Kogarah, Australia.
Förderung
- Australian Government Research Training Program Scholarship
Zitieren
APA
Lielkajis, M. D., Rosenfeld, A. B., Guatelli, S., Metcalfe, P. E., Poder, J., Bucci, J. A., & Cutajar, D. L. (2026). Diffusing alpha‐emitters radiation therapy dosimetry: Geant4 multi‐stage Monte Carlo modeling of sources. Medical Physics, 53(6). https://doi.org/10.1002/mp.70494
Vancouver
Lielkajis MD, Rosenfeld AB, Guatelli S, Metcalfe PE, Poder J, Bucci JA, et al. Diffusing alpha‐emitters radiation therapy dosimetry: Geant4 multi‐stage Monte Carlo modeling of sources. Medical Physics. 2026;53(6). doi:10.1002/mp.70494
BibTeX
@article{Lielkajis2026,
author = {Lielkajis, Mitchell D and Rosenfeld, Anatoly B and Guatelli, Susanna and Metcalfe, Peter E and Poder, Joel and Bucci, Joseph A and Cutajar, Dean L},
title = {Diffusing alpha‐emitters radiation therapy dosimetry: Geant4 multi‐stage Monte Carlo modeling of sources},
journal = {Medical Physics},
year = {2026},
volume = {53},
number = {6},
doi = {10.1002/mp.70494}
}
EUVIMED